TROUBLESHOOTING & REPAIR | ||||||
|
| |||||
| Observe all Safety Guidelines detailed throughout this manual |
| ||||
|
|
|
|
| ||
PROBLEMS |
| POSSIBLE AREAS OF |
| RECOMMENDED | ||
(SYMPTOMS) |
| MISADJUSTMENT(S) |
| COURSE OF ACTION | ||
|
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
|
|
|
|
|
| |
Major Physical or | Electrical | Contact the Lincoln Electric |
|
|
| |
Damage is Evident. |
|
| Service Dept. (216) |
|
|
|
|
|
| or |
|
|
|
|
|
|
| |||
The Machine is dead - The Input | 1. Check for blown or missing | 1. | The.Start/Stop button (S1) | |||
contactor does not | operate. |
| fuses in input lines. |
| may be faulty- Check for prop- | |
|
|
|
|
| er operation. See wiring dia- | |
|
| 2. | Check the |
| gram. |
|
|
|
| line voltage at the machine. |
|
|
|
|
|
| The input voltage must match | 2. | The Control Transformer (T2) | |
|
|
| the rating plate and reconnect |
| may be faulty. Perform the | |
|
|
| panel. |
| Control Transformer Test. | |
|
|
|
| 3. | The primary or secondary | |
|
|
|
|
| thermostats may be open. | |
|
|
|
|
| Check or replace. Also check | |
|
|
|
|
| the associated wiring. See | |
|
|
|
|
| wiring diagram. | |
|
|
|
| 4. | The pilot relay (2CR) may be | |
|
|
|
|
| faulty. Check or replace. See | |
|
|
|
|
| wiring diagram. | |
|
|
|
| 5. | The input contactor coil may | |
|
|
|
|
| be open. See wiring diagram. | |
|
|
|
| 6. | The Control board may be | |
|
|
|
|
| faulty - Replace. | |
|
|
|
|
| ||
Input contactor (1CR) chatters. | 1. | The input line voltage may be | 1. | The pilot relay (2CR) may | ||
|
|
| low. Check all three phases. |
| have bad contacts. Check or | |
|
|
|
|
| replace relay. | |
|
| 2. Make sure input line voltage |
|
|
| |
|
|
| matches machine rating and | 2. | Check for loose or faulty | |
|
|
| reconnect panel. |
| wiring between pilot relay | |
|
|
|
|
| (2CR) and input contactor | |
|
|
|
|
| (1CR) | coil connections. |
|
|
|
| 3. | The input contactor (1CR) | |
|
|
|
|
| may be | faulty - Replace. |
|
|
|
|
|
|
|