| TROUBLESHOOTING & REPAIR | ||||
|
|
| |||
| Observe all Safety Guidelines detailed throughout this manual |
| |||
|
|
|
|
|
|
| PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
| (SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
|
OUTPUT PROBLEMS
The machine does not have max- imum weld output.
1.Check all
2.Put output control switch (SW3) in “OUTPUT CON- TROL AT
1.Check the output control potentiometer (R1) and asso- ciated circuitry for loose or faulty connections. See wiring diagram.
2.Perform Control Board Test.
3.Perform Firing Board test.
4.Perform Main Transformer Test.
5.Perform SCR Output Bridge Test.
Return to Section TOC
Return to Master TOC
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call