TROUBLESHOOTING & REPAIR | ||
|
|
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE
LOADED - 500 AMP OUTPUT TERMINAL
CONSTANT VOLTAGE INNERSHIELD MODE
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
This is the typical DC open circuit volt- age waveform generated from a proper- ly operating machine. Note that each vertical division represents 20 volts and that each horizontal division represents 2 milliseconds in time. The machine was loaded with a resistance grid bank. The grid bank meters read 400 amps at 36 VDC.
Note: Scope probes connected at
machine ouput terminals: (+) probe to positive 500 amp terminal,
SCOPE SETTINGS
Volts/Div. . . . . . . . . . . . . 20 V/Div. Horizontal Sweep . . . . . 2 ms/Div. Coupling . . . . . . . . . . . . . . . . . DC Trigger . . . . . . . . . . . . . . . Internal