Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING & REPAIR | ||
|
|
CONTROL TRANSFORMER (T2) VOLTAGE TEST
WARNING
Service and repair should be performed only by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment could result in danger to the technician or the machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical trou- bleshooting assistance before you proceed.
Call (216)
_____________________________________________________________
TEST DESCRIPTION
This test will determine if the correct voltage is being:
a.applied to the primary of the control transformer.
b.induced on the secondary winding of the control transformer.
MATERIALS NEEDED
Volt/Ohm Meter (Multimeter)
IDEALARC