Friedrich CP05 CP Line operation manual Installation Instructions, Window Requirements

Page 9

Installation Instructions

Window Requirements

NOTE: All supporting parts should be firmly secured to wood, or metal.

1.This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 14" from the bottom of the sash to the window sill.

2.If storm window presents interference, fasten a 2" wide wood strip (OUTER SILL) to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Fig. 5-2. Top of wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside.

3.Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as

shown Fig. 5-2.

4.If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strip are not necessary.

 

 

 

 

 

L BRACKET

INNER

 

WOOD STRIP MOUNTED

1" MAX.

3/4"

SILL

 

ON TOP OF INNER SILL

 

 

 

 

 

 

CLEARANCE

 

 

 

 

 

STORM

 

 

 

INNER

 

WINDOW

 

 

 

 

FRAME

 

 

 

SILL

 

 

 

 

 

WOOD STRIP

 

 

 

 

FOR L BRACKET

 

 

 

OUTER

 

 

OUTER

 

 

SILL

 

 

SILL

INDOORS

Fig. 5-1

OUTDOORS

INDOORS

Fig. 5-2

OUTDOORS

 

 

 

 

Installation

 

 

 

HARDWARE

 

 

 

TYPE A: 11EA

TYPE B: 5EA

 

TYPE C: 3EA

(SHORT SCREW)

(WOOD SCREW)

(L BRACKET)

10mm

16mm

 

 

TYPE D: 1EA

TYPE E: 1EA

TYPE F: 2EA

TYPE G: 1EA

(SEAL STRIP)

(SASH SEAL)

(GUIDE PANEL)

(SUPPORT BRACKET)

(Adhesive backed)

(Not adhesive backed)

 

 

ENGLISH

9

Image 9
Contents Room Air Conditioner Table of Contents Introduction Before Operating Your UnitFor the Best Cooling Performance and Energy Efficiency Never Do This Always Do This Safety PrecautionsSharp Edges Control and Remote Control Operations How to operate your FriedrichAir Direction Care and MaintenanceFeatures Features and InstallationWindow Requirements Installation InstructionsBegin Installation Before InstallationInstall the AIR Conditioner in the Window Locating Unit in WindowInstall the Sash Seal and Sash Lock Removal from WindowSecure the Guide Panels Electrical Safety Electrical DataImportant Grounding Instructions Troubleshooting Tips Normal OperationAbnormal Operation Room AIR Conditioners Limited Warranty De votre climatiseur de pièce CP Line Table des matières Nutilisez Jamais un fil de rallonge Avant dutiliser votre appareilAvertissement Mesures de Sé curitéBords Aiguisés Instructions de Fonctionnement Fonctionnement des commandes et de la té lé commandeNettoyage et Entretien La Direction de LairCaracté ristiques Instructions dinstallationMAX Instructions dinstallationAvant L Installation Placez Lappareil Dans LA FenêtreAttachez LE Support EN L Installz LA Bande ET LE Verrou DE LA Glissière LE Retrait DE LA FenêtreAttachez LES Panneaux Coulissants Instructions d installation Lutilisation DE Cordons ProlongateursInstructions Importantes Relatives a LA Mise a LA Terre Avant de placer un appel de service Fonctionnement normalFonctionnement anormal Garantie Limité E -PREMIÈ RE Anné E Garantie limité e Climatiseurs FriedrichRegistrar su acondicionador de aire para habitación Contenidos Antes de poner en funcionamiento su unidad IntroducciónAdvertencia Precaucion Precauciones Importantes de SeguridadPrecaucion Funcionamiento de los controles y del mando a distancia Instruccionnes de FuncionamientoCuidado y Mantenimiento La direcció n del airePara Limpiar EL Filtro Limpieza DEL Aire AcondicinadoCaracterísticas Requerimientos de la VentanaRequerimientos de la ventana Instrucciones para la instalació nEmpieze LA Instlacion Antes DE InstalarColoque EL Ménsula EN L Instale EL Aire Acondicionado a LA VentanaAsegure LOS Paneles Instale LA Banda DEL MarcoRemoverlo DE LA Ventana Utilice un fusible de 15AMP. o un Interruptor de 15AMP Antes de avisar al Servicio Té cnico Operació n normalOperació n anormal Garantia Limitada -PRIMER AÑ O Friedrich AIR Conditioning CO