Hitachi SJ700-2 Series service manual Fef Fuf Avr

Page 10

 

 

 

 

 

Default

 

 

 

Code

Function name

Monitored data or setting

 

 

 

Note

 

 

 

 

_FF

_FEF

_FUF

 

 

 

 

 

 

 

 

 

AVR

A081

AVR function select

00 (always on), 01 (always off), 02 (off during deceleration)

02

00

00

 

A082

AVR voltage select

200 V class: 200, 215, 220, 230, 240 (V)

200/400

230/400

230/460

 

 

400 V class: 380, 400, 415, 440, 460, 480 (V)

 

 

 

 

 

 

 

 

 

A085

Operation mode selection

00 (normal operation), 01 (energy-saving operation), 02 (fuzzy operation)

 

00

 

 

 

A086

Energy saving mode tuning

0.1 to 100.0

 

50.0

 

 

 

A092

Acceleration (2) time setting

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

15.00

 

 

 

A292

Acceleration (2) time setting,

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

15.00

 

 

function

2nd motor

 

 

 

 

 

 

 

 

 

A392

Acceleration (2) time setting,

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

15.00

 

 

3rd motor

 

 

 

 

 

 

 

 

 

acceleration/deceleration

A093

Deceleration (2) time setting

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

15.00

 

 

A293

Deceleration (2) time setting,

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

15.00

 

 

2nd motor

 

 

 

 

 

 

 

 

 

A393

Deceleration (2) time setting,

0.01 to 99.99, 100.0 to 999.9, 1000. to 3600. (s)

 

15.00

 

 

3rd motor

 

 

 

 

 

 

 

 

 

A094

Select method to switch to

00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only

 

00

 

 

Acc2/Dec2 profile

when rotation is reversed)

 

 

 

 

 

 

 

 

A294

Select method to switch to

00 (switching by 2CH terminal), 01 (switching by setting), 02 (switching only

 

00

 

 

and

 

 

 

Acc2/Dec2, 2nd motor

when rotation is reversed)

 

 

 

 

 

 

 

 

mode

A095

Acc1 to Acc2 frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

transition point

 

 

 

 

 

 

 

 

 

Operation

A295

Acc1 to Acc2 frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

transition point, 2nd motor

 

 

 

 

 

 

 

 

 

A096

Dec1 to Dec2 frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

 

 

transition point

 

 

 

 

 

 

A296

Dec1 to Dec2 frequency

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

 

transition point, 2nd motor

 

 

 

 

 

 

 

 

 

 

 

A097

Acceleration curve selection

00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)

 

00

 

 

 

A098

Deceleration curve setting

00 (linear), 01 (S curve), 02 (U curve), 03 (inverted-U curve), 04 (EL-S curve)

 

00

 

 

 

A101

[OI]-[L] input active range start

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

 

A102

[OI]-[L] input active range end

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

 

frequency

 

 

 

 

 

 

 

 

 

 

adjustment

A103

[OI]-[L] input active range start

0. to "[OI]-[L] input active range end current" (%)

 

20.

 

 

current

 

 

 

 

 

 

 

 

 

A104

[OI]-[L] input active range end

"[OI]-[L] input active range start current" to 100. (%)

 

100.

 

 

current

 

 

 

frequency

 

 

 

 

 

 

 

A105

[OI]-[L] input start frequency

00 (external start frequency), 01 (0 Hz)

 

00

 

 

enable

 

 

 

 

 

 

 

 

 

A111

[O2]-[L] input active range start

-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

External

frequency

 

 

 

 

 

 

 

 

 

A112

[O2]-[L] input active range end

-400. to -100., -99.9 to 0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

frequency

 

 

 

 

A113

[O2]-[L] input active range start

-100. to 02 end-frequency rate (%)

 

-100.

 

 

 

voltage

 

 

 

 

 

 

 

 

 

 

 

A114

[O2]-[L] input active range end

"02 start-frequency rate" to 100. (%)

 

100.

 

 

 

voltage

 

 

 

 

 

 

 

 

 

 

n and deceleratio

A131

Acceleration curve constants

01 (smallest swelling) to 10 (largest swelling)

 

02

 

 

setting

 

 

 

 

 

 

 

 

 

A132

Deceleration curve constants

01 (smallest swelling) to 10 (largest swelling)

 

02

 

 

setting

 

 

 

 

 

Operation-target frequency

00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via

 

 

 

 

frequency

A141

OI), 04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string

 

02

 

 

selection 1

 

 

 

 

frequency input)

 

 

 

 

 

 

 

 

 

 

A142

Operation-target frequency

00 (digital operator), 01 (keypad potentiometer), 02 (input via O), 03 (input via

 

03

 

 

Operation-target

selection 2

OI), 04 (external communication), 05 (option 1), 06 (option 2), 07 (pulse-string

 

 

 

 

frequency input)

 

 

 

 

 

 

 

 

 

 

A143

Operator selection

00 (addition: A141 + A142), 01 (subtraction: A141 - A142), 02 (multiplication:

 

00

 

 

A141 x A142)

 

 

 

 

 

 

 

 

 

A145

Frequency to be added

0.00 to 99.99, 100.0 to 400.0 (Hz)

 

0.00

 

 

A146

Sign of the frequency to be

00 (frequency command + A145), 01 (frequency command - A145)

 

00

 

 

 

 

 

 

 

added

 

 

 

 

 

 

 

 

 

 

 

A150

EL-S-curve acceleration

0. to 50. (%)

 

25.

 

 

Acceleration and deceleration

ratio 1

 

 

 

 

 

 

 

 

 

A151

EL-S-curve acceleration

0. to 50. (%)

 

25.

 

 

ratio 2

 

 

 

 

 

 

 

 

 

A152

EL-S-curve deceleration

0. to 50. (%)

 

25.

 

 

ratio 1

 

 

 

 

 

 

 

 

 

A153

EL-S-curve deceleration

0. to 50. (%)

 

25.

 

 

 

 

 

 

 

ratio 2

 

 

 

 

 

 

 

 

 

 

1 - 6

Image 10
Contents SJ700-2 Series NTS204X Table of contents Appendix Specification labelModel name,Manufacturing numberMFG Investigation of the inverterPrecautions for Data Setting Function Mode Extended Function Mode PID FEF FUF AVR Electronic thermal characteristic, 2nd B034 Free-setting V/f frequency To 400. Hz FEF FUF FEF FUF FF FEF FUF Term inal C111 FEF FUF FEF FUF RPM Specification FEF FUF FEF FUF Code display system and key operations Page Corresponding to the function code. Data display *1*2 Example of operation in full display mode b037 = STR key after changing the dataPressing the STR key Troubleshooting Inverter trip contents,remedy,adviseCPU GA.COM Adjust Option boards error codes OFFInput mode specified by switch settings Setting of MAC ID DIP switches No to No Error code is output when the relevant program runs Trip conditions monitoring 305 A004/A204/A304 A202/A220/A320 *2 006 Initialization setting Page Debug Mode Monitor ModesFunction Modes Inverter Setting Setting procedureConfirming the completion of initialization HFF/-HFUF/-HFEFControl signal VDCPage Daily inspection CleaningPeriodic inspection Daily and Periodic Inspections Ground Resistance Test with a Megger Method of Checking the Inverter and Converter Circuits Replacing Parts Page Page Inverter Replacement Control board SJ700-055-110LF**2 Circuit Diagram SJ700-150LF**2 185LF**2 Circuit Diagram Ground Terminal With JumperSJ700-220LF**2 Circuit Diagram SJ700-300LF**2 Circuit Diagram SJ700-370LF**2 Circuit Diagram SJ700-450LF**2 Circuit Diagram Driver BoardSJ700-550LF**2 Circuit Diagram SJ700-055-110HF**2 Circuit Diagram SJ700-150HF**2 Circuit Diagram SJ700-185HF**2 220HF**2 Circuit Diagram Circuit Diagram SJ700-300HF**2SJ700-370HF**2 Circuit Diagram TMC CN1 Page Page Page Page Page Page Page Page Page Page Page