2) Mounting the molded-case type of smoothing capacitors

(note)This feature to remove the smoothing capacitor easily is not available for the mold case type(up to 11Kw) <1> Place the capacitor unit on the capacitor mounting plate.

<2> Fit both edges of the capacitor mounting plate into the guide grooves in the inverter casing, and then insert the plate into the inverter.

<3> Secure the capacitor board to the main circuit terminal block by using the connection terminal screws. <4> Fix the capacitor mounting plate to the inverter casing by using the screws.

<5> Mount the backing plate.

<6> Mount the terminal block cover.

3)Removing the sheet-metal-case type of smoothing capacitors <1> Remove the terminal block cover.

<2> Make sure that the Charge lamp goes off.

<3> Remove the lower screws from terminal block terminals P and N. <4> Remove the screws fixing the capacitor mounting plate.

<5> Pull down the capacitor mounting plate.

<6> Remove the busbar and resistors, and then remove the capacitor unit from the capacitor mounting plate.

4)Mounting the sheet-metal-case type of smoothing capacitors

<1> Set the capacitor unit on the capacitor mounting plate and secure the unit in place by using the screws.

<2> Mount the busbar and resistors in the original positions, and then secure these parts in place by using the screws. <3> Fit the capacitor mounting plate into the inverter casing.

<4> Fix the capacitor mounting plate to the inverter casing by using the screws. <5> Attach the lower screws to terminal block terminals P and N.

<6> Mount the terminal block cover.

<3>

<5>

<4>

5 - 7

Image 53
Contents SJ700-2 Series NTS204X Table of contents Appendix Investigation of the inverter Specification labelModel name,Manufacturing numberMFGPrecautions for Data Setting Function Mode Extended Function Mode PID FEF FUF AVR Electronic thermal characteristic, 2nd B034 Free-setting V/f frequency To 400. Hz FEF FUF FEF FUF FF FEF FUF Term inal C111 FEF FUF FEF FUF RPM Specification FEF FUF FEF FUF Code display system and key operations Page Corresponding to the function code. Data display *1*2 STR key after changing the data Example of operation in full display mode b037 =Pressing the STR key Inverter trip contents,remedy,advise TroubleshootingCPU GA.COM Adjust OFF Option boards error codesInput mode specified by switch settings Setting of MAC ID DIP switches No to No Error code is output when the relevant program runs Trip conditions monitoring 305 A004/A204/A304 A202/A220/A320 *2 006 Initialization setting Page Monitor Modes Debug ModeFunction Modes Setting procedure Inverter SettingHFF/-HFUF/-HFEF Confirming the completion of initializationVDC Control signalPage Periodic inspection CleaningDaily inspection Daily and Periodic Inspections Ground Resistance Test with a Megger Method of Checking the Inverter and Converter Circuits Replacing Parts Page Page Inverter Replacement Control board SJ700-055-110LF**2 Circuit Diagram Ground Terminal With Jumper SJ700-150LF**2 185LF**2 Circuit DiagramSJ700-220LF**2 Circuit Diagram SJ700-300LF**2 Circuit Diagram SJ700-370LF**2 Circuit Diagram Driver Board SJ700-450LF**2 Circuit DiagramSJ700-550LF**2 Circuit Diagram SJ700-055-110HF**2 Circuit Diagram SJ700-150HF**2 Circuit Diagram SJ700-185HF**2 220HF**2 Circuit Diagram SJ700-300HF**2 Circuit DiagramSJ700-370HF**2 Circuit Diagram TMC CN1 Page Page Page Page Page Page Page Page Page Page Page