Hitachi SJ700-2 Series service manual Example of operation in full display mode b037 =

Page 27

1.3.2Example of operation in full display mode ("b037" = "00")

All parameters can be displayed in full display mode. The display sequence of parameters matches their sequence shown in Chapter 8, "List of Data Settings."

Key operation and

transition of codes on display (in monitor or function mode)

Key operation and

transition of monitored

data on display (in monitor

or function mode)

Key operation and

transition of codes on display (in extended function mode)

Key operation and

transition of monitored

data on display (in

extended function mode)

Pressing the

1

or 2 key respectively scrolls up or down the code displayed in code display mode or

increases or decreases the numerical data displayed in data display mode.

Press the 1

or

2 key until the desired code or numerical data is shown. To scroll codes or

increase/decrease numerical data fast, press and hold the key.

Monitor mode

FUNC

FUNC or STR

Function mode

FUNC

*1 The content of the display varies depending on the parameter type.

(Monitor

*2 To update numerical data, be sure to press the

STR key after changing the data.

display)

(*1)

 

FUNC or STR

FUNC

FUNC

FUNC

FUNC

FUNC

FUNC

FUNC or STR

(Data display)

(*1) (*2)

FUNC or STR

FUNC or STR

FUNC or STR

FUNC or STR

FUNC or STR

For the display and key operation in extended function mode U, see the next page.

(*1) (*2)

(Data display)

Extended function mode A

FUNC

FUNC or STR

Extended function mode B

Extended function mode C

Extended function mode H

Extended function mode P

1 - 23

Image 27
Contents SJ700-2 Series NTS204X Table of contents Appendix Investigation of the inverter Specification labelModel name,Manufacturing numberMFGPrecautions for Data Setting Function Mode Extended Function Mode PID FEF FUF AVR Electronic thermal characteristic, 2nd B034 Free-setting V/f frequency To 400. Hz FEF FUF FEF FUF FF FEF FUF Term inal C111 FEF FUF FEF FUF RPM Specification FEF FUF FEF FUF Code display system and key operations Page Corresponding to the function code. Data display *1*2 STR key after changing the data Example of operation in full display mode b037 =Pressing the STR key Inverter trip contents,remedy,advise TroubleshootingCPU GA.COM Adjust OFF Option boards error codesInput mode specified by switch settings Setting of MAC ID DIP switches No to No Error code is output when the relevant program runs Trip conditions monitoring 305 A004/A204/A304 A202/A220/A320 *2 006 Initialization setting Page Monitor Modes Debug ModeFunction Modes Setting procedure Inverter SettingHFF/-HFUF/-HFEF Confirming the completion of initializationVDC Control signalPage Cleaning Daily inspectionPeriodic inspection Daily and Periodic Inspections Ground Resistance Test with a Megger Method of Checking the Inverter and Converter Circuits Replacing Parts Page Page Inverter Replacement Control board SJ700-055-110LF**2 Circuit Diagram Ground Terminal With Jumper SJ700-150LF**2 185LF**2 Circuit DiagramSJ700-220LF**2 Circuit Diagram SJ700-300LF**2 Circuit Diagram SJ700-370LF**2 Circuit Diagram Driver Board SJ700-450LF**2 Circuit DiagramSJ700-550LF**2 Circuit Diagram SJ700-055-110HF**2 Circuit Diagram SJ700-150HF**2 Circuit Diagram SJ700-185HF**2 220HF**2 Circuit Diagram SJ700-300HF**2 Circuit DiagramSJ700-370HF**2 Circuit Diagram TMC CN1 Page Page Page Page Page Page Page Page Page Page Page