Outback Power Systems GS8048 manual MATE3 System Display and Controller

Page 8

Introduction

MATE3 System Display and Controller

The Radian inverter/charger has no external controls. It can operate normally without an external control or interface. Basic modes and settings are pre-programmed at the factory. (See page 47 for default settings.) The Radian inverter has no display or LED indicators. It is not possible to monitor its status or operating mode without a metering device.

The MATE3 System Display and Controller (sold separately) is an OutBack product designed to accommodate programming and monitoring of an OutBack power system. The MATE3 provides the means to adjust the factory default settings to correctly match the installation where needed. It also provides the means to monitor system performance and troubleshoot fault or shutdown conditions.

Once settings are modified using a MATE3, the MATE3 can be removed from the installation. The settings are stored in the non-volatile memory of the Radian. However, it is highly recommended to include a MATE3 as part of the system. This provides the means to monitor system performance and respond quickly should it be necessary to correct a fault or shutdown condition.

The MATE3’s Configuration Wizard is capable of automatically configuring inverters to a series of preset values. This is often more efficient than attempting to manually program each setting in each inverter. Affected fields include system type, battery charging, and AC source configuration. (For more information, see the MATE3 OWNERS MANUAL).

NOTE: The Radian Series Inverter/Charger can only be used with MATE3 firmware revision 002.005.xxx or higher.

IMPORTANT:

Some functions are not based in the inverter, but are part of the MATE3 system display’s firmware. They will not function if the system display is removed. These functions are listed beginning on page 32. For a detailed description of functions and programming, please see the MATE3 OWNERS

MANUAL.

Figure 2 MATE3 System Display and Controller

6

900-0020-01-00 Rev A

Image 8
Contents Radian Series Inverter/Charger GS8048Trademarks Symbols Used AudienceDefinitions Terms and DefinitionsGeneral Safety Important Safety InstructionsTable of Contents List of Figures Table of ContentsList of Tables Introduction MATE3 System Display and Controller Pre-startup Procedures CommissioningFunctional Test StartupPowering Down Firmware UpdatesAdding New Devices CommissioningGenerator OperationInput Modes Support OperationGrid Tied UPS Uninterruptible Power Supply Backup Mini GridOperation Functions InvertingSearch InputAC Current Settings AC Source AcceptanceTransfer Offset Battery Charging Charging StepsNo Charging Bulk StageOffset Charging Stages Over Time1Float Timer SilentFloat Stage Repeated SilentNew Absorption Stage Absorption TimerNew Charging Cycle Battery Temperature Compensation EqualizationExamples Multiple-Inverter Installations Stacking OutBack HUB4 and MATE3Example of Parallel Stacking Arrangement Three Inverters Power Save Levels Auxiliary Terminals Operation Operation High Battery Transfer System Display-Based FunctionsAdvanced Generator Start AGS Grid Use TimeTroubleshooting Symptom Possible Cause Possible Remedy TroubleshootingBasic Troubleshooting Symptom Possible Cause Possible Remedy TroubleshootingTroubleshooting Hot or neutral Not be bonded Inverter may be behaving correctly Inverter output is being fed Troubleshooting Error Messages Error Troubleshooting Message Causes Possible RemedyMessage Definition Possible Remedy AC Freq Too HighCapacitors Disconnect Messages Voltage MaximumSell Status Definition Sell StatusSell Status Messages Troubleshooting Specifications Specifications for Model GS8048Electrical Specifications for Model GS8048 Value Mechanical Specifications for Model GS8048Environmental Specifications Regulatory SpecificationsSpecifications Environmental Specifications for All Models ValueFirmware Revision Default Settings and RangesGS8048 Inverter Settings Field Default Minimum Maximum OutBack Power Technologies Product RegistrationExtended Warranty Product RegistrationWarranty Year Limited Warranty for Radian ProductsHow to Arrange for Warranty Service TroubleshootingReturn Material Authorization RMA WarrantyOut of Warranty Returning Product to OutBackThis page Intentionally Left Blank Year Warranty IndexIndex Input Modes 11, 17, 20, 22This page Intentionally Left Blank