8.Tilt the blade to 45° and repeat Steps
9.If the blade was parallel to the miter slot at 90° but not at 45°, the table will need to be shimmed with metal shim stock. The shims are placed under the table over each of the three table mounting bolts.
10.Refer to Figures 82 and 83 for shim place- ment. If the distance of A is shorter than B, shim(s) will need to be placed under corners #1 and #2. If the distance of B is shorter than A, shim(s) will need to be placed under cor- ner #3. Very thin shim stock works well.
11.Tighten down one bolt a small amount and then move on to each of the others, tighten- ing each down the same amount. Continue to rotate through the bolts, tightening them a little each time until they are all secure.
12.Now recheck the blade to miter slot at 90° and 45° by repeating Steps
13.Once you feel you have the miter slot adjust- ed to the blade, recheck all measurements and be sure the table mounting bolts are secure. Also, if you ever remove the table in the future, be sure to make note of shim placements and reassemble exactly how it came apart.