Figure 87. Sliding table release knob.
4.Pull the blade guard away from the blades to expose the arbor nut as shown in Figure 88. (The internal blade guard is held in place with a magnet.)
5.Remove the main blade.
Figure 88. Scoring blade arbor nut.
6.Place a 23mm wrench behind the scoring blade on the flats of the arbor shaft, and use a 22mm wrench at the front to remove the arbor nut and flange, as shown in Figure 89 (turn counter-clockwise).
Figure 89. Loosening scoring blade arbor nut.
7.Remove the scoring blade set and replace with a new set that is stacked to the same kerf thickness as the main blade.
8.Install the flange and arbor nut, and tighten the arbor nut in the reverse order of step 5.
9.Move the orange blade guard back into its original position, next to the blades, and move the sliding table to its original position over the blades.
10.Align the scoring blade to the main blade as described in the “Aligning Scoring Blade Set” instructions in this manual.
G0501 Sliding Table Saw | -49- |