Grizzly G0501 Calibrating Blade Tilt, To change the belt on the scoring blade motor

Page 55

To change the belt on the scoring blade motor:

1.Move the blade tilt to 0˚ on the control panel (blade 90˚ to table), and raise the main blade and scoring blade set up as far as they will go.

2.Disconnect the saw from the power source!

3.Open the motor cabinet door.

4.Jack up the scoring blade motor with a bottle jack, as shown in Figure 91, to loosen the belt. Note—Use wood blocks to raise the bot- tle jack.

Calibrating Blade

Tilt

The blade tilt is calibrated at the factory, but can be adjusted if it changes during the life of the machine.

To calibrate the blade tilt:

1.Move the blade tilt to 0˚ on the control panel (blade 90˚ to table), and raise the main blade as far as it will go.

2.Place a machinist’s square on the table and against the blade.

3.Adjust the blade tilt until the blade is perfect- ly square with the table.

4.At the control panel, press SET.

5.Press 0.

Figure 91. Jacking up scoring motor with a bot-

tle jack to remove the belt.

5.Remove the old belt and install a new belt in the center of the pulleys.

6.Let the jack down, so the weight of the motor tensions the belt.

7.Remove the jack and wood blocks, and close the motor cabinet door.

6.Press and hold down SET for five seconds. This new setting will now be stored in the control panel.

G0501 Sliding Table Saw

-53-

Image 55
Contents Sliding Table SAW Page Table Of Contents Maintenance Safety Instructions for Power Tools Safety25ft 50ft 100ft Length AMP RatingAdditional Safety Instructions for Table Saws Protecting Yourself From Kickback Preventing KickbackBelow are tips to reduce the likelihood of kick- back Glossary Of Terms Commentary General InformationCircuit Requirements 220V 3-PhaseTypical locking type L15-20 plug Receptacle 440V 3-PhaseGrounding Extension Cords To rewire the Model G0501 for 440V opera- tion Rewiring toMain Features Features & ControlsBlades Control Panel Blade Guard Controls Fence Assembly Lock Down LeverLeveling Adjustment Locking Lever Rip Fence ControlsMain Crate SET UPAbout this Section Piece Inventory UnpackingSaw unit Crosscut fence components Hardware Recognition Chart Working Clearances Clean Up Site ConsiderationsMoving & Placing Saw Base Unit Control panel correctly set up Table InstallationTo install the sliding table Access panel removed one side Shown To install the blade guard Installing Blade GuardTo install the extension tables Installing Extension TablesLarge extension table installed G0501 Sliding Table Saw Rip Fence To install the rip fenceTo assemble the crosscut table Crosscut TableMounting Shaft Miter Fence To install the miter fenceTest Run To adjust the sliding table parallel with the main blade Sliding Table Parallel AdjustmentTo align the fence scale with the blade Fence Scale AlignmentTo connect the dust ports to a dust collection system Dust CollectionOperation Tips OperationsPlease follow these tips Every time you use your saw Changing Blade Speeds Changing Blade TiltTo change the blade tilt To align the scoring blade set Aligning Scoring Blade SetRip cutting with the sliding table Rip CuttingRip fence set even with center Blade G0501 Sliding Table Saw Rip cutting using the traditional table saw techniqueCrosscutting Crosscutting full size panels Crosscutting using the rip fence as a cut-off gaugeCrosscutting smaller panels Miter Cutting Mount the miter fence onto the sliding table To perform a miter cutTo change main blade Changing Main BladeTo change the riving knife Changing Riving KnivesTo change scoring blade set Changing Scoring Blade SetPage Belts MaintenanceCleaning MiscellaneousDate Approximate Hours Of Use Maintenance Performed Maintenance LogTo change the V-belt on the main motor Service AdjustmentsAbout Service Replacing BeltsTo change the belt on the scoring blade motor Calibrating Blade TiltTo calibrate the blade tilt To align the riving knife Adjusting Riving Knife AlignmentTo square the crosscut fence with the blade Squaring Crosscut Fence to BladeRepeat steps Replacement Blades Aftermarket AccessoriesReference Info Machine Data Sheet Scoring Motor Sliding Table SAW Capacities G0501 Machine Frame Assembly G0501 Machine Frame/Saw Angle Measurement Assemblies G0501 Saw Angle Measurement AssemblyG0501 G0501 Chip Channel Assembly G0501 Saw Blade Adjustment Assembly PSB64M G0501 Main Saw Assemblies Bracket G0501 Scoring Saw Assemblies Description G0501 Swinging Arm Assembly Cleaning Brush 3LIDINGD4ABLEBANDN-ITERT&ENCEN!SSEMBLIES %&HaYc\IVWaZHVl G0501 Crosscut Table Square Plug G0501 Crosscut Fence Helical Pressure Spring G0501 Machine Table Assemblies Extension Table G0501 Rip Fence Assembly TOP Section G0501 Blade Guard Assembly Support ARM G0501 Electrical Panel Components Digital Control Display DP-525 Symptom Possible Cause Possible Solution Motor TroubleshootingPerformance Troubleshooting G0501 Control Panel Back Side Diagram G0501 Electrical Panel Warranty and Returns Warranty Card BOX BELLINGHAM, WA Grizzly INDUSTRIAL, INCPage Call Today For a Free Full Color Catalog