Black & Decker 492848-00 Maintenance, Clean and Inspect Daily, Troubleshooting, Accessories

Page 10

492848-00,BDN200 NAILER 2/2/06 1:35 PM Page 10

MAINTENANCE

CLEAN AND INSPECT DAILY

Disconnect tool from air supply before cleaning and inspection. Correct all problems before placing the tool back in use.

Wipe tool clean and inspect for wear or damage. Use non-flammable cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK tool with cleaning solutions. Such solutions can damage internal parts.

Inspect trigger and safety mechanism to assure system is complete and functional: no loose or missing parts, no binding or sticking parts.

Keep all screws tight. Loose screws can cause personal injury or damage tool.

If tool is used without an in-line oiler: place five or six drops of air tool oil into the tool’s air inlet on a daily basis.

IMPORTANT: To assure product SAFETY and RELIABILITY, repairs, maintenance and adjustment (other than those listed in this manual) should be performed by authorized service centers or other qualified service organizations, always using identical replacement parts.

TROUBLESHOOTING

Disconnect tool from air supply before performing any Service

Procedure.

SYMPTOM PROBLEMSSOLUTIONS

1.Air leak near top of tool or in trigger area.

Loose screws.

Tighten screws.

Worn or damaged

B&D service for overhaul.

o-rings or seals.

 

2.Tool does nothing or operates sluggishly.

Inadequate air supply.

Verify adequate air supply.

Inadequate lubrication.

Put 5 or 6 drops of oil into air inlet.

Worn or damaged

B&D service for overhaul.

o-rings or seals.

 

3.Air leak near bottom of tool.

Loose screws.

Tighten screws.

Worn or damaged

B&D service for overhaul.

o-rings or bumper.

 

4.

Tool jams frequently. Incorrect fasteners.

Verify approved fasteners of

 

 

correct size.

 

Damaged fasteners.

Replace w/undamaged fasteners.

 

Magazine or nose

Tighten screws.

 

screws loose.

 

 

Magazine is dirty.

Clean magazine.

 

Driver is worn or damaged. B&D service for driver maintenance.

 

 

 

5.

Other.

Contact a Black & Decker

 

 

Service Facility.

ACCESSORIES

Recommended accessories for use with your tool are available from your local retailer.

The use of any accessory not recommended for use with this tool could be hazardous.

10

Image 10
Contents Brad Nailer Safety Guidelines / Definitions General Safety RulesNever point tool at yourself or others in work Do not use tool without safety warning label. If Driving a nail into another nail may also cause a spark. Fig 492848-00,BDN200 Nailer 2/2/06 135 PM Functional Description Power SourcePreparing the Tool Using the Tool Operating InstructionsClearing a Jammed Fastener Troubleshooting MaintenanceClean and Inspect Daily AccessoriesService Information Full TWO-YEAR Home USE WarrantyRègles Générales DE Sécurité Lignes Directrices EN Matière DE Sécurité / DéfinitionsConservez CES Directives Utilisez de l’air comprimé propre, sec 492848-00,BDN200 Nailer 2/2/06 135 PM 492848-00,BDN200 Nailer 2/2/06 135 PM 492848-00,BDN200 Nailer 2/2/06 135 PM Source D’ALIMENTATION Description FonctionnellePréparation DE L’OUTIL Directives D’UTILISATION Utilisation DE L’OUTILDégagement D’UN Clou Coincé Entretien Inspection ET Nettoyage QuotidiensSymptôme Problèmes Solutions DépannageInformation SUR LES Réparations AccessoiresGarantie Complète DE Deux ANS Pour Usage Résidentiel Normas Generales DE Seguridad Normas DE Seguridad DefinicionesConserve Estas Instrucciones Regulado de 4,8 a 8,3 bar 70 a PSI. Fig 492848-00,BDN200 Nailer 2/2/06 135 PM 492848-00,BDN200 Nailer 2/2/06 135 PM 492848-00,BDN200 Nailer 2/2/06 135 PM Fuente DE Energía Descripción DE LAS FuncionesPreparación DE LA Herramienta Instrucciones DE Operación USO DE LA HerramientaRemoción DE UN Sujetador Atascado Mantenimiento Limpie E Inspeccione DiariamenteDetección DE Problemas Síntoma ProblemassolucionesInformación DE Servicio AccesoriosGarantía Completa DE DOS Años Para USO EN EL Hogar PUEBLA, PUE CULIACAN, SIN MONTERREY, N.LGUADALAJARA, JAL MEXICO, D.F