To deactivate the automatic
the operating mode button 2 pressed for at least 3 s (while the measuring tool is switched on). Deactivation of the automatic
!WARNING Do not leave the switched o n m e a s u r i n g t o o l
unattended and switch the measuring tool off after use. Other persons could be blinded by the laser beam. To activate the automatic
Operating Modes
The measuring tool has four operating modes between which you can switch at any time:
–
–
–Horizontal line operation: The measuring tool generates a horizontal laser line facing frontward.
–Vertical line operation: The measuring tool generates a vertical laser line facing frontward.
All point beams run at a 90° angle to each other; the laser lines also cross each other at a 90° angle. After switching on, the measuring tool is in
mode button 2.
All operating modes can be selected both with and without automatic levelling.
Automatic Levelling
Working with Automatic Levelling (see figures
firm support, attach it to the holder 15 or to the tripod 16.
When working with automatic levelling, push the On/Off switch 4 to the “ on” position.
soon as the measuring tool is within the self- levelling range of ±4°, the laser beams light up continuously. In case of ground vibrations or position changes during operation, the measuring tool is automatically levelled in again. To avoid errors by moving the measuring tool, check the position of the laser beams with regard to the reference points upon
Working without Automatic Levelling (see figure F)
For work without automatic levelling, push the On/Off switch 4 to the “ on” position. When the automatic levelling is switched off, the laser lines flash continuously.
When automatic levelling is switched off, you can hold the measuring tool freely in your hand or place it on an inclinded surface. The laser beams no longer necessarily run vertical to each other.
Levelling Accuracy
Influences on Accuracy
The ambient temperature has the greatest influence. Especially temperature differences occurring from the ground upward can divert the laser beam.
As thermal fluctuation is largest close to the ground, the measuring tool, if possible, should be mounted on a commercially available tripod and placed in the centre of the working area.
Apart from exterior influences,
After switching on, the automatic levelling f u n c t i o n a u t o m a t i c a l l y c o m p e n s a t e s irregularities within the
Set up the measuring tool in level position and wait for the