ADJUSTING THE TABLE iNSERT
(Fig. ii)
[,A WARNING]
To avoid serious injury, the table
insert (2) must be level with the table, if the table insert is not flush
with the table, adjust the two bolts
(1)with a 4 mm he× wrench until it is parallel with the table.
NOTE: To raise the insert, turn the hex screws counterclockwise. To lower the insert, turn the hex screws clockwise.
Do not remove the insert, adjustments need to be made with the insert in
place to get the proper level.
Fig. II
REMOVING THE BLADE (Fig. S, T, U)
I,,A WARNING]
To avoid injury from an accidental start, make sure the switch is in the OFF position and the plug is disconnected from the power source outlet.
1.Remove the table insert by snapping out from the hole (8). (Fig. S)
2.Raise the blade to the maximum
height by turning the blade elevation handwheel clockwise.
3.Adjust the blade to the 90 ° vertical position by unlocking the blade
tilting lock knob, push in the blade elevation wheel and turn the bevel
tilting handwheel counterclockwise, and then lock into position.
4.Place the
5.Place the
6.Then remove the blade. Clean but do not remove the inner blade flange before reassembling the blade.