1.Remove the Hydraulic Pump Cover from the console.
2.Locate the Check Valve Adjusting Screw as shown below:
Check Valve
Adjusting Screw
3.Turn the Check Valve Adjusting Screw clockwise to increase the raise speed and counterclockwise to decrease the raise speed.
4.Replace the Hydraulic Pump Cover.
The lowering speed can be adjusted as follows: NOTES: If the machine will not lower check to see if the Depth Lock has been activated. For additional information on the Depth Lock see the section Depth Lock on page 22.
1.Remove the Hydraulic Pump Cover from the console.
2.Located the Inline Flow Control Valve as shown in the picture below. NOTE: The Inline Flow Control Valve only affects the lowering speed not the raise speed.
41