Graco H50, H40, H25 Temperature Controls and Indicators, Main Power Switch, Red Stop Button

Page 18

Temperature Controls and Indicators

Temperature Controls and Indicators

NOTICE

To prevent damage to the softkey buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.

Heater Power Indicators

Zone A Arrow Keys

A

Zone B Arrow Keys B

Hose Zone Arrow Keys

Actual Temperature

Key

Target Temperature Key

FIG. 4. Temperature Controls and Indicators

Heater Displays

Heater A On/Off

Key

Heater B On/Off

Key

Hose Heater On/Off

Key

°F

Temperature Scale

°C Keys

Main Power Switch

Located on right side of unit, page 17. Turns

Reactor power ON

and OFF

.

Does not turn heater zones or pumps on.

 

Red Stop Button

Located between temperature control panel and motor control panel, page 17. Press

to shut off motor and heater zones

only. Use main power switch to shut off all power to unit.

18

312062W

Image 18
Contents Important Safety Instructions OperationContents Systems GCP2R2 Models SeriesXP2 Series ApprovalsReactor Hydraulic Proportioner Part Description Reactor Electrical DiagramsSupplied Manuals Part DescriptionRelated Manuals Electric Shock Hazard Skin Injection Hazard Pressurized Aluminum Parts Hazard Material Self-ignition Important Two-Component Material InformationIsocyanate Conditions Keep Components a and B SeparateFoam Resins with 245 fa Blowing Agents Changing MaterialsSide Supply Detail Typical Installation, with circulationKey for FIG Side Supply Detail MTypical Installation, without circulation Typical Installation, without circulationComponent Identification Detail of Reactor Fluid Manifold shroud removed for clarity Detail of Serial No Plate inside cabinetTemperature Controls and Indicators Main Power SwitchRed Stop Button Temperature Scale Keys/LEDs Actual Temperature Key/LEDTarget Temperature Key/LED Temperature Arrow KeysCircuit Breakers Size ComponentPark Key/LED Motor Controls and IndicatorsMotor ON/OFF Key/LED PSI/BAR Keys/LEDs Pressure Key/LEDHydraulic Pressure Control Knob Spray AdjustmentsCycle Count Key/LED Motor Control Arrow KeysSetup Locate ReactorGeneral equipment guidelines Electrical Requirements Phase Amps WattsElectrical Requirements KW/Full Load Amps Full Load Voltage Peak System PartConnect electrical cord Power Cord RequirementsCord Specification Part Model AWG mmConnect feed pumps Install Fluid Temperature Sensor FTS Connect pressure relief linesConnect whip hose to gun fluid mani- fold Connect heated hoseClose gun fluid manifold valves a and B Pressure check hoseLubrication system setup Ground systemCheck hydraulic fluid level Startup Check generator fuel levelSet temperatures Manual current control mode only Change pressure imbalance setting optional Set pressureAvailable Pressure Imbalance Settings PSI BARSpraying Open gun fluid manifold valves a and B Standby Shutdown Pressure Relief Procedure Fluid Circulation LationCirculation Through Gun Manifold Diagnostic Codes Code Code Name Alarm ZoneMotor Control Diagnostic Codes Code Code Name Alarm orMaintenance Frequency of Oil Changes Ambient Recommended TemperatureFluid Inlet Strainer Screen Fluid Inlet StrainerPump Lubrication System Pump Lubrication SystemFlushing Dimensions Dimension In. mmTop View Technical Data Category DataPerformance Charts Foam Performance ChartCoatings Performance Chart 110 Flow Rate in gpm lpmGraco Standard Warranty Graco Information