Maintenance

Fluid Inlet Strainer Screen

The inlet strainers filter out particles that can plug the pump inlet check valves. Inspect the screens daily as part of the startup routine, and clean as required.

Use clean chemicals and follow proper stor- age, transfer, and operating procedures, to minimize contamination of the A-side screen.

Clean the A-side screen only during daily startup. This minimizes moisture contamination by immediately flushing out any isocyanate residue at the start of dispensing operations.

1.Close the fluid inlet valve at the pump inlet and shut off the appropriate feed pump. This prevents material from being pumped while cleaning the screen.

2.Place a container under the strainer mani- fold (59d) to catch fluid. Remove the strainer plug (59j).

3.Remove the screen (59g) from the strainer manifold. Thoroughly flush the screen with compatible solvent and shake it dry.

Inspect the screen. If more than 25% of the mesh is blocked, replace the screen. Inspect the gasket (59h) and replace as required.

4.Ensure the pipe plug (59k) is screwed into the strainer plug (59j). Install the strainer plug with the screen (59g) and gasket (59h) in place and tighten. Do not overtighten. Let the gasket make the seal.

5.Open the fluid inlet valve, ensure that there are no leaks, and wipe the equipment clean. Proceed with operation.

59d

59g*

59h

59j 59k

ti9886a

FIG. 6. Fluid Inlet Strainer

*See Reactor Repair-Parts manual 312063 for fluid filter screen replacements.

312062W

45

Image 45
Contents Operation Important Safety InstructionsContents Systems GCP2R2 Series ModelsApprovals XP2 SeriesSupplied Manuals Reactor Electrical DiagramsReactor Hydraulic Proportioner Part Description Part DescriptionRelated Manuals Electric Shock Hazard Skin Injection Hazard Pressurized Aluminum Parts Hazard Isocyanate Conditions Important Two-Component Material InformationMaterial Self-ignition Keep Components a and B SeparateChanging Materials Foam Resins with 245 fa Blowing AgentsKey for FIG Typical Installation, with circulationSide Supply Detail Side Supply Detail MTypical Installation, without circulation Typical Installation, without circulationComponent Identification Detail of Serial No Plate inside cabinet Detail of Reactor Fluid Manifold shroud removed for clarityTemperature Controls and Indicators Main Power SwitchRed Stop Button Target Temperature Key/LED Actual Temperature Key/LEDTemperature Scale Keys/LEDs Temperature Arrow KeysSize Component Circuit BreakersMotor ON/OFF Key/LED PSI/BAR Keys/LEDs Motor Controls and IndicatorsPark Key/LED Pressure Key/LEDCycle Count Key/LED Spray AdjustmentsHydraulic Pressure Control Knob Motor Control Arrow KeysSetup Locate ReactorGeneral equipment guidelines Electrical Requirements KW/Full Load Amps Phase Amps WattsElectrical Requirements Full Load Voltage Peak System PartCord Specification Power Cord RequirementsConnect electrical cord Part Model AWG mmConnect feed pumps Connect pressure relief lines Install Fluid Temperature Sensor FTSClose gun fluid manifold valves a and B Connect heated hoseConnect whip hose to gun fluid mani- fold Pressure check hoseLubrication system setup Ground systemCheck hydraulic fluid level Check generator fuel level StartupSet temperatures Manual current control mode only Set pressure Change pressure imbalance setting optionalPSI BAR Available Pressure Imbalance SettingsSpraying Open gun fluid manifold valves a and B Standby Shutdown Pressure Relief Procedure Lation Fluid CirculationCirculation Through Gun Manifold Code Code Name Alarm Zone Diagnostic CodesCode Code Name Alarm or Motor Control Diagnostic CodesFrequency of Oil Changes Ambient Recommended Temperature MaintenanceFluid Inlet Strainer Fluid Inlet Strainer ScreenPump Lubrication System Pump Lubrication SystemFlushing Dimensions Dimension In. mmTop View Category Data Technical DataPerformance Charts Foam Performance ChartCoatings Performance Chart Flow Rate in gpm lpm 110Graco Information Graco Standard Warranty