Startup
9. Set pressure
ON / OFF
PARK
PSI
BAR
Motor Controls and Indicators, see page 21
a. Press to display the pressure
reading.
b.Press motor . Motor and pumps start. Display shows system pressure.
Motor must rotate counterclockwise when viewed from shaft end. See Con- nect electrical cord, page 25.
c.Adjust hydraulic pressure control until display shows desired fluid pressure.
+-
ti7731ati7732a
If display pressure is greater than desired pressure, reduce the hydraulic pressure and trigger gun to reduce pressure.
Check the pressure of each proportion- ing pump using the component A and B gauges. The pressures should be approximately equal and must remain fixed.
d. To display cycle count, press .
To clear counter, press and hold
for 3 sec.
e. Press PSI or BAR to change pres-
sure scale.
10.Change pressure imbalance setting (optional)
The pressure imbalance function (status code 24, page 43) detects conditions that can cause
Code 24 (pressure imbalance) is set to an alarm as the default. To change to a warning, see Reactor
The pressure imbalance default is
a. Turn main power switch OFF | . |
312062W | 33 |