Spraying
Spraying
1. Engage gun piston safety lock.
ti2409a
2. Close gun fluid manifold valves A and B.
ti2728a
3.Attach gun fluid manifold. Connect gun air line. Open air line valve.
ti2543a
4. Set PRESSURE RELIEF/SPRAY valves
(SA, SB) to SPRAY | . |
SA
SB
ti9877a
5.Check that heat zones are on and tempera- tures are on target, page 31.
6.Press motor to start motor and pumps.
7.Check fluid pressure display and adjust as necessary.
8.Check fluid pressure gauges (GA, GB) to ensure proper pressure balance. If imbal- anced, reduce pressure of higher compo- nent by slightly turning PRESSURE RELIEF/SPRAY valve for that component toward PRESSURE RELIEF/CIRCULA-
TION , until gauges show balanced pressures.
GAGB
In this example, B side
pressure is higher, so
use the B side valve to balance pressures.
ti9877a
312062W | 35 |