Graco H40, H50 Connect heated hose, Close gun fluid manifold valves a and B, Pressure check hose

Page 28

8. Connect heated hose

See Heated Hose manual 309572 for detailed instructions on connecting heated hoses.

The fluid temperature sensor (C) and whip hose (D) must be used with heated hose, see page 27. Hose length, including whip hose, must be 60 ft (18.3 m) minimum.

a. Turn main power OFF

.

b.Assemble heated hose sections, FTS, and whip hose.

c.Connect A and B hoses to A and B out- lets on Reactor fluid manifold (FM). Hoses are color coded: red for compo- nent A (ISO), blue for component B (RES). Fittings are sized to prevent con- nection errors.

FM

N

A

P

B

ti9878a

Manifold hose adapters (N, P) allow use of 1/4 in. and 3/8 in. ID fluid hoses. To use 1/2 in. (13 mm) ID fluid hoses, remove adapters from fluid manifold and install as needed to connect whip hose.

Setup

d.Connect cables (Y). Connect electrical connectors (V). Be sure cables have slack when hose bends. Wrap cable and electrical connections with electri- cal tape.

Y

V

ti9881a

9. Close gun fluid manifold valves A and B

ti2411a

10.Connect whip hose to gun fluid mani- fold

Do not connect manifold to gun.

ti2417a

11. Pressure check hose

See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.

28

312062W

Image 28
Contents Important Safety Instructions OperationContents Systems GCP2R2 Models SeriesXP2 Series ApprovalsReactor Electrical Diagrams Supplied ManualsReactor Hydraulic Proportioner Part Description Part DescriptionRelated Manuals Electric Shock Hazard Skin Injection Hazard Pressurized Aluminum Parts Hazard Important Two-Component Material Information Isocyanate ConditionsMaterial Self-ignition Keep Components a and B SeparateFoam Resins with 245 fa Blowing Agents Changing MaterialsTypical Installation, with circulation Key for FIGSide Supply Detail Side Supply Detail MTypical Installation, without circulation Typical Installation, without circulationComponent Identification Detail of Reactor Fluid Manifold shroud removed for clarity Detail of Serial No Plate inside cabinetMain Power Switch Temperature Controls and IndicatorsRed Stop Button Actual Temperature Key/LED Target Temperature Key/LEDTemperature Scale Keys/LEDs Temperature Arrow KeysCircuit Breakers Size ComponentMotor Controls and Indicators Motor ON/OFF Key/LED PSI/BAR Keys/LEDsPark Key/LED Pressure Key/LEDSpray Adjustments Cycle Count Key/LEDHydraulic Pressure Control Knob Motor Control Arrow KeysLocate Reactor SetupGeneral equipment guidelines Phase Amps Watts Electrical Requirements KW/Full Load AmpsElectrical Requirements Full Load Voltage Peak System PartPower Cord Requirements Cord SpecificationConnect electrical cord Part Model AWG mmConnect feed pumps Install Fluid Temperature Sensor FTS Connect pressure relief linesConnect heated hose Close gun fluid manifold valves a and BConnect whip hose to gun fluid mani- fold Pressure check hoseGround system Lubrication system setupCheck hydraulic fluid level Startup Check generator fuel levelSet temperatures Manual current control mode only Change pressure imbalance setting optional Set pressureAvailable Pressure Imbalance Settings PSI BARSpraying Open gun fluid manifold valves a and B Standby Shutdown Pressure Relief Procedure Fluid Circulation LationCirculation Through Gun Manifold Diagnostic Codes Code Code Name Alarm ZoneMotor Control Diagnostic Codes Code Code Name Alarm orMaintenance Frequency of Oil Changes Ambient Recommended TemperatureFluid Inlet Strainer Screen Fluid Inlet StrainerPump Lubrication System Pump Lubrication SystemFlushing Dimension In. mm DimensionsTop View Technical Data Category DataFoam Performance Chart Performance ChartsCoatings Performance Chart 110 Flow Rate in gpm lpmGraco Standard Warranty Graco Information