c.400V, 3 phase: Using 5/32 or 4 mm hex allen wrench, connect three power leads to L1, L2, and L3. Connect neutral to N. Connect green to ground (GND).
GND
L1
L3
L2 N
ti2725a
Some
5.Connect feed pumps
a.Install feed pumps (K) in component A and B supply drums. See FIG. 1 and FIG. 2, pages 14 and 15.
A minimum feed pressure of 50 psi (0.35 MPa, 3.5 bar) is required at both feed inlet pressure gauges (FP). Maxi- mum feed pressure is 250 psi (1.75 MPa, 17.5 bar). Maintain A and B feed pressures within 10% of each other.
FP
ti10006a
b.Seal component A drum and use desic- cant dryer (M) in vent.
Setup
c.Install agitator (L) in component B drum, if necessary.
d.Ensure A and B inlet valves (FV) are closed.
FV
ti9883a
Supply hoses from feed pumps should be 3/4 in. (19 mm) ID.