Graco 310624F manual Pressurized Equipment Hazard

Page 7

WARNINGS

WARNINGS

Pressurized Equipment Hazard

Compressed air can inject in skin. Air tubing rupture can cause injury if disconnected while under pressure. To reduce risk of injury:

Never exceed maximum working pressure of any attachment.

Do not direct airstream at body.

Follow Pressure Relief Procedure, page 16 whenever you are instructed to relieve pressure, stop spraying, service equipment, install or clean spray nozzle or disconnect or connect hose.

Cleaning Solvent Hazard with Plastic Parts

Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. Many solvents can degrade plastic parts to the point where they could fail. Such failure could cause serious injury or property damage. See Technical Data on page 37 of this instruction manual and in all other equipment manuals. Read fluid and solvent manufacturer’s warnings.

Personal Protective Equipment

Wear appropriate protective equipment when operating, servicing or when in the operating area of this equipment to help protect yourself from serious injury, including eye injury, inhalation of toxic fumes, burns and hearing loss. This equipment includes, but is not limited to:

protective eye wear

clothing and respirator as recommended by fluid and solvent manufacturer

hearing protection

gloves

CAUTION

Water or material remaining in unit when temperatures are below freezing can damage pump and/or delay startup.

To insure water and material are completely drained out of unit:

remove hose from material outlet,

tip sprayer forward 45° to allow material (water) to flow out of pump inlet.

Before adding material or starting unit in cold weather, circulate warm water through pump.

310624F

7

Image 7 Contents
Maximum materiaalwerkdruk 100 psi 6,9 bar Models Page 3 / Modèles Page 4/ Modellen Blz310624F Model Country Manual Languages ModelsManual Model Electric Country Languages RequirementsModèle Pays Manuel Langues ModèlesManuel Modèle Spécification Pays Langues ÉlectriqueModel Land Handleiding Talen ModellenHandleiding Model Elektrische Land VereistenEquipment Misuse Hazard Fire and Explosion HazardElectric Shock Hazard Pressurized Equipment Hazard Mises EN Garde Equipement de protection individuel Gevaar voor elektrische schokken VoorzichtigBrand- en explosiegevaar Gevaren bij verkeerd gebruik van de apparatuurGevaar van reinigingsvloeistoffen bij kunststof onderdelen Gevaar van apparatuur onder drukUitrusting voor persoonlijke bescherming Ti4500a English Français Nederlands Function Fonction Functie System Priming / Amorçage / Het systeem vullen inspuitenTi4005a Preparation / Préparation / Voorbereiding Grounding / Mise à la masse / Aarding Luchtcompressor Extension Cords Auxiliary Air CompressorRallonges Compresseur d’air Auxiliaire Verlengsnoeren BijkomendeGénérateurs Longueurs de flexible Generators Hose LengthsGeneratoren Slanglengtes Setup / Installation / Opstellen De vultrechter C verwijderen De vultrechter C installeren Removing Hopper C Installing Hopper CDémontage de la trémie C Montage de la trémie C Wetting Hose / Mouillage du flexible / De slang bevochtigen Waste Mixing Material / Mélange / Materiaal mengen Preparation / Préparation / Voorbereiding Startup / Démarrage / Opstarten Waste English Français Open air valve aa Réglage du débit de Réglage du débit d’air Produit Material Flow Air Flow AdjustmentDe materiaalstroom De luchtstroom afstellen Afstellen Ti4006a Relâcher la pression en suivant la Une fois la pulvérisation terminée When you have finished sprayingWanneer u klaar bent met spuiten Ti4012a See Gun Manual 310616 for Needle removal/repair ’eau résiduelle Utilisation Maintenance / Maintenance / OnderhoudTechnical Data Caractéristiques Techniques Technische gegevens Page For Graco Canada Customers Warranty / Garantie / GarantieGraco Headquarters Minneapolis