Carrier 30RAP010-060 Scrolling Marquee Display Menu Structure, Mode RUN Service Temperatures

Page 5

Table 2 — Scrolling Marquee Display Menu Structure*

MODE

RUN

SERVICE

TEMPERATURES

PRESSURES

SET

INPUTS

OUTPUTS

CONFIGURATION

TIME

OPERATING

ALARMS

STATUS

TEST

POINTS

CLOCK

MODES

 

Auto

Service

Ent and Leave Unit

Pressures

Cooling

General

General

Display

Time of

 

 

 

View of

Modes

Current

 

Test Mode

Temps

Ckt A

Setpoints

Inputs

Outputs

Configuration

Day

 

Run Status

(MODE)

(CRNT)

 

(TEST)

(UNIT)

(PRC.A)

(COOL)

(GEN.I)

(GEN.O)

(DISP)

(TIME)

 

(VIEW)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Run

Outputs

Temperatures

Pressures

Head

Circuit

Outputs

Unit

Month,

 

Reset

 

Hour and

Pressure

Circuit A

Date, Day,

 

 

and Pumps

Ckt A

Ckt B

Inputs

Configuration

 

Alarms

 

Start

Setpoint

EXV

and Year

 

 

(OUTS)

(CIR.A)

(PRC.B)

(CRCT)

(UNIT)

 

(RCRN)

 

(RUN)

(HEAD)

(A.EXV)

(DATE)

 

 

 

 

 

 

 

 

 

 

Compressor

Ciruit A Comp

Temperatures

 

Brine

4-20mA

Outputs

Unit Options 1

Daylight

 

Alarm

 

 

Freeze

Circuit B

Savings

 

 

Run Hours

Test

Ckt B

 

Inputs

Hardware

 

History

 

 

Setpoint

EXV

Time

 

 

(HOUR)

(CMPA)

(CIR.B)

 

(4-20)

(OPT1)

 

(HIST)

 

 

(FRZ)

(B.EXV)

(DST)

 

 

 

 

 

 

 

 

 

 

 

Compressor

Ciruit B Comp

 

 

 

 

Outputs

Unit Options 2

Local

 

 

 

 

 

 

 

Holiday

 

 

 

Starts

Test

 

 

 

 

Circuit A

Controls

 

 

 

 

 

 

 

Schedules

 

 

 

(STRT)

(CMPB)

 

 

 

 

(CIR.A)

(OPT2)

 

 

 

 

 

 

 

(HOL.L)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Local

 

 

 

Preventive

 

 

 

 

 

Outputs

CCN Network

Occu-

 

 

 

Maintenance

 

 

 

 

 

Circuit B

Configuration

pancy

 

 

 

(PM)

 

 

 

 

 

(CIR.B)

(CCN)

Schedule

 

 

 

 

 

 

 

 

 

 

 

(SCH.L)

 

 

 

Software

 

 

 

 

 

 

Head Pressure

Schedule

 

 

 

Version

 

 

 

 

 

 

Comp. Delta

Override

 

 

SUB-MODE

(VERS)

 

 

 

 

 

 

(HP.A)

(OVR)

 

 

 

 

 

 

 

 

 

Head Pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp. Delta

 

 

 

 

 

 

 

 

 

 

 

(HP.B)

 

 

 

 

 

 

 

 

 

 

 

Cir. A EXV

 

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

(EXV.A)

 

 

 

 

 

 

 

 

 

 

 

Cir. B EXV

 

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

(EXV.B)

 

 

 

 

 

 

 

 

 

 

 

Motormaster

 

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

(MM)

 

 

 

 

 

 

 

 

 

 

 

Reset Cool Temp

 

 

 

 

 

 

 

 

 

 

 

(RSET)

 

 

 

 

 

 

 

 

 

 

 

Set Point and

 

 

 

 

 

 

 

 

 

 

 

Ramp Load

 

 

 

 

 

 

 

 

 

 

 

(SLCT)

 

 

 

 

 

 

 

 

 

 

 

Service

 

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

(SERV)

 

 

 

 

 

 

 

 

 

 

 

Broadcast

 

 

 

 

 

 

 

 

 

 

 

Configuration

 

 

 

 

 

 

 

 

 

 

 

(BCST)

 

 

 

LEGEND

Ckt — Circuit

*Throughout this text, the location of items in the menu structure will be described in the following format:

Item Expansion (Mode NameSub-mode NameITEM)

For example, using the language selection item:

Language Selection (ConfigurationDISPLANG)

5

Image 5
Contents Contents Controls, Start-Up, Operation, Service, and TroubleshootingSafety Considerations ContentsBasic Controls Usage GeneralUnit Sizes Unit Nominal Capacity TonsAccessory Navigator Display Module SET Inputs Outputs Configuration Time Operating Alarms Mode RUN Service TemperaturesScrolling Marquee Display Menu Structure TestStrt Run Status Mode and Sub-Mode DirectoryVers SUB-MODE Keypad Display SUB-ITEM Comment Entry ExpansionSUB-MODE Keypad Display Comment Entry Expansion Test Service Test Mode and Sub-Mode DirectoryOuts CmpaSet Points Mode and Sub-Mode Directory Temperature Mode and Sub-Mode DirectoryPressure Mode and Sub-Mode Directory Outputs Mode and Sub-Mode Directory Inputs Mode and Sub-Mode DirectorySUB-MODE Keypad Display Comment Entry Expansion EXV Configuration Mode and Sub-Mode DirectorySUB-MODE Keypad Display Comment Entry Expansion Unit OPT1OPT2 SUB-MODE Keypad Display CommentXXX XXX.X ΔF DST Time Clock Mode and Sub-Mode DirectoryDate Alarms Mode and Sub-Mode Directory Operating Mode and Sub-Mode DirectoryOperating Modes Mode Item Expansion DescriptionCarrier Comfort Network CCN Interface ControlsControl Module Communication Thermistor Designations CCN Communication Bus WiringStatus Inputs Output RelaysAUX AlmrCCB CHCA30-4963 A30-4962Typical Control Box for 30RAP035-060 A30-4964Typical Wiring Schematic, 30RAP018-030 Units Power Wiring A30-4966 Typical Wiring Schematic, 30RAP018-030 Units Control Wiring5283 Typical Wiring Schematic, 30RAP035-060 Units Power WiringA30-5284 Typical Wiring Schematic, 30RAP035-060 Units Control WiringA30-4968 A30-4967Page CEPL130351 30RAP Unit Size Control Capacity Steps Capacity % Deadband MultiplierOperating Envelope for R-410A Compressor A30-496930RAP Unit Size FAN Stages Cooling Set Point SelectA30-4970 Control Methods and Cooling Set Points Optional Factory-Installed Hydronic PackControl Occupancy Cooling SET Point Select Clsp Type State CCN→PM1E = YES Configuring and Operating Dual Chiller Con Rset Dual Chiller Configuration Master Chiller ExampleSUB-MODE Keypad Entry Display Item Expansion Comments PartNumber Rset Slave Complete Dual Chiller Configuration Slave Chiller ExampleMenu Configuration of 4 to 20 mA Cooling Set Point Control To 20 mA ResetConfiguring Return Temperature Reset Configuring Outdoor Air and Space Temperature ResetMode Keypad SUB Display RED LED Entry ModeOutdoor-Air Temperature Reset To 20-mA Demand Limiting Item Expansion Comment Entry Configuration Configuring Demand LimitPRE-START-UP System Check30RAP Minimum Cooler Flow Maximum Cooler Flow Size START-UP and OperationA30-4978 Operating Limitations Temperature Limits for Standard 30RAP UnitsOperation Sequence Unit Size 30RAElectronic Components ServiceEXV Steps Unit Size 30RAP EXV StepsElectronic Expansion Valve Details A30-4971Unit Torque Specification Compressor Replacement Refer to FigCooler A30-4972Check Refrigerant Feed Components Oil ChargeLWT A30-4973A30-4974 Unit Cutout CUT-IN Factory Settings, High-Pressure Switch FixedCheck Unit Safeties Thermistor Well Temp Voltage Resistance Drop 100,260 143 Drop 86K Thermistor vs Resistance DTTA30-499 A30-4975A30-4976 AccsyP50 Fault History Last 8 faults P51 Software version A30-4977 Mode Nominal Voltage Control Input Start JumperTB1-TB2 TB13A-TB2Fault Codes PID Parameters Description ModeMotormaster V Program Parameters for Operating Modes Replacement Replacement Part Module MaintenanceReplacement Modules Troubleshooting 30RAP Unit Cutout CUT-IN Size Advanced Scroll Temperature Protection LabelSymptoms Cause Remedy TroubleshootingT051 Alarm and Alert CodesT110 T153 T197 CCN Alert GENERATED?CSB EMMCompressor Stuck on Failure Alarms Page SUB-MODE Display Item Description Comment Appendix a Display TablesView RUNVers Appendix a Display TablesStrt Pressures Mode and Sub-Mode Directory Cool SUB-MODE Display Item Description Range CommentHead FRZGEN.O SUB-MODE Display Item Description Comment HP.B HP.AEXV.B EXV.ARset Bcst Date SUB-MODE Display Item Description Comment TimeDST HOL.LHD.19 HD.30 SCH.L SUB-MODE Display Item Description Comment SCH.NPER.1 PER.2PER.8 PER.6PER.7 Hist CrntRcrn CCN Display Tables Aunit General Unit Parameters Appendix B CCN TablesCCN Display Tables Circaan Circuit a Analog Parameters Description Value Units Point Name ForcibleCCN Display Tables Circban Circuit B Analog Parameters Appendix B CCN TablesCCN Configuration Tables OPTIONS1 Options 1 Configuration CCN Configuration Tables Unit Unit ConfigurationDescription Value Default Units Point Name CCN Display Tables Options Unit ParametersCCN Configuration Tables Schedovr Timed Override Setup CCN Configuration Tables OPTIONS2 Options 2 ConfigurationCCN Configuration Tables Mmconf Motormaster Configuration CCN Configuration Tables Display Marquee Display SetupCCN Service Tables Service Description Value Point Name Description Value Units Point NameDescription Version Value CCN Maintenance Tables AlarmsCCN Maintenance Tables PM-PUMP CCN Maintenance Tables Runtest CCN Maintenance Tables Dualchil Setting Appendix C Factory Settings for Pump and Manual StartersOptional BACnet Communications Wiring Appendix D Optional Bacnet Communications WiringTable a SW3 Protocol Switch Settings For MS/TP Appendix D Optional Bacnet Communications WiringTable B Baud Selection Table DS8 DS7 DS6 DS5 DS4 DS3Specification Recommmendation Table C MS/TP Wiring RecommendationsAWG CL2PCMP Wiring Specifications Recommended Vendors and Part NumbersRmcorp LED Status Table E LED Status IndicatorsRUN LED Error LED Status Table G Network Points List Control Mode108 109 30RAP Maintenance Interval Requirements Appendix E Maintenance Summary and LOG SheetsWeekly Quarterly30RAP Weekly Maintenance Log Appendix E Maintenance Summary and LOG SheetsPSI 30RAP Monthly Maintenance LogUnit Section Action Entry 113 30RAP Seasonal Shutdown LogCopyright 2010 Carrier Corporation Remove and use for Job File Project Information START-UP Checklist for 30RAP Liquid ChillerII. Preliminary Equipment Check Design InformationStart and Operate Machine. Complete the Following III. Unit Start-UpDual Chiller Control Only Record Software Versions Mode RUN StatusOPTIONS1 Options Configuration Unit Configuration SettingsSubmode Item Expansion Display Entry OPT1CCN CCN Network Configuration OPTIONS2 Options ConfigurationHP.A Head Pressure Cmp. Delta Configuration HP.B Head Pressure Cmp. Delta ConfigurationEXV.B Circuit B EXV Configuration EXV.A Circuit a EXV ConfigurationMM Motormaster Configuration Settings EXV.BSlct Setpoint and Ramp Load Configuration Rset Reset Configuration SettingsSetpoint Entry Expansion SUB-MODE Keypad Display Comment
Related manuals
Manual 40 pages 58.51 Kb

30RAP010-060 specifications

The Carrier 30RAP010-060 is a series of rooftop air conditioning units designed for effective climate control in commercial applications. Engineered with advanced technologies, these units are known for their reliability, energy efficiency, and ease of installation, making them a suitable choice for a range of settings including offices, retail spaces, and industrial facilities.

One of the standout features of the 30RAP series is its robust construction. Designed to withstand various environmental conditions, these units come equipped with a weather-resistant cabinet and a corrosion-resistant finish. This durability ensures long-term performance and reduced maintenance costs.

Energy efficiency is a significant characteristic of the Carrier 30RAP series. These units utilize advanced technologies such as a high-efficiency compressor and variable speed fans. The inclusion of economizers also contributes to energy savings by allowing the system to take advantage of outdoor air when the conditions are favorable. With high SEER (Seasonal Energy Efficiency Ratio) ratings, the 30RAP units help businesses reduce operating costs while minimizing their environmental footprint.

The 30RAP series is equipped with smart control systems that provide enhanced operational efficiency and comfort. With features such as programmable thermostats and remote access capabilities, building managers can easily monitor and adjust the system to maintain optimal indoor climate conditions. Additionally, the units are compatible with building automation systems, allowing for seamless integration into a larger HVAC network.

The installation process of the Carrier 30RAP010-060 is streamlined thanks to a compact design and lightweight construction, which simplifies the transportation and placement on rooftops. Moreover, the unit's modular components facilitate easy access for maintenance and repairs, minimizing downtime and improving overall reliability.

In summary, the Carrier 30RAP010-060 series stands out for its combination of durability, energy efficiency, and advanced control technologies. It is an ideal solution for businesses seeking reliable climate control systems that balance performance with cost-effectiveness. Whether for new installations or replacements, these rooftop units provide the necessary flexibility and efficiency needed in today’s commercial environments. With strong backing from Carrier, a leader in HVAC technology, the 30RAP series ensures lasting comfort and operational efficiency.