Dukane 403-570-01 user manual 18Weld Torque Trigger Option Screen

Page 43

Section 5 - Touch Screen Menus

Torque Trigger Option

This option specifies a torque level to sense when the

upper and lower parts make contact. Prior to contact, the motor is spinning the tool in the air using a very low amount torque. At contact, there is an increase in the torque required to maintain a constant angular velocity,

at which point the weld is considered to start (i.e. the weld timer and counter are started). Note that the welder begins to sense the torque after reaching the TRIGGER

Position. To enable this option, press the Torque Trigger button and then the Enable box on the screen shown in

Figure 5-18. The Torque (% of max..) field specifies the

torque level at which the weld will start. The Timeout

(s)value specifies the amount of time the welder will wait between reaching the TRIGGER Position and the sensing of the torque trigger. If torque trigger does not occur within this time, the machine will abort the cycle and display an error. The DONE button causes a return to the main WELD tab screen.

For this option to work properly, the torque trigger value must be set above the torque required to keep the spin tool running before part contact (i.e. in free air). To set the torque trigger value correctly, follow these steps:

1.Program all welder settings as desired (refer to other sections in this manual if needed).

2.Disable the Torque Trigger Option.

3.Verify that the VERTICAL TRAVEL LOWER LIMIT is set properly to prevent the possibility of contact between the tool and fixture (refer to

TOOLS, SYSTEM SETUP tab menu).

4.Press the RUN button.

5.Run a “dry” cycle (i.e. without parts) by acti- vating both RUN switches until the spin motor stops.

6.Read the Peak Torque (%) value on the RUN screen. This value represents the torque re- quired to keep the tool spinning in the air.

7.Repeat Steps 5 and 6 several times to determine the largest torque value.

8.Enable the Torque Trigger Option and set the

Torque (% of max..) field to be slightly larger (at least 2%) than the number from the previous step.

Figure 5–18Weld Torque Trigger Option Screen

Dukane Manual Part No. 403-570-01

Page  37

Image 43
Contents Dual Servo Spin Welder Dukane Manual Part No Revision Revision HistorySummary Date This page intentionally left blank Dukane Dual Servo Spin Welder ContentsThis page intentionally left blank Introduction SectionDukane Manual Part No Read This Manual First Important User InformationDrawings and Tables SVT042VR Dual Servo Spin Welder OverviewKey Dual Servo Spin Welder Features This page intentionally left blank Safety Considerations This page intentionally left blank  Caution Health and Safety TipsGeneral Safety Run SwitchesPlastics Health Notice Mechanical Safety Electrical SafetyAC Power Receptacle This page intentionally left blank Unpacking and Setup This page intentionally left blank Qty Part Number Unpacking WelderPacking List Work AreaMounting Holes Securing to Work BenchBench Capacity LevelingTooling Hub & Fixture Dimensions are in Inches mm20-Amp 240V Figure AC PowerUser I/O Connector Head Height AdjustmentControl Connectors Base Interface ConnectorThis page intentionally left blank Display and Controls This page intentionally left blank 1Dual Servo Spin Welder Touch Screen Panel Touch Screen DisplayEmergency Stop Switch Operational SwitchesOpti-Touch Run Switches Data I/O ConnectorBrigtly Lit Red LEDs This page intentionally left blank View Parts Touch Screen MenusThis page intentionally left blank Screen Layout RUN ModeView Parts PRE-WELD Setup Setup MenuTool Setup Trigger Position TOP of Stroke PositionPre-Spin Orientation Option Part Pickup OptionWeld Method Selection Weld SetupTime Method Distance Method Rotation MethodOrientation Option Energy Method18Weld Torque Trigger Option Screen Torque Trigger OptionHold Setup POST-WELD SetupConstant Torque Option 22Hold Setup Screen for Distance Mode 25Process Limit Definitions Screen 1 Part Tests28RUN Screen with Part Test Failed Button Tools Menu Select Setup TabUtilities Tab Third tab is labeled System Setup and is shown in Figure System Setup Tab34Vertical Lower Limit Setup Screen with Set Position Button 35Password-Protected Screens and Menus Setting Time and Date On Touch Screen Parameter Value Range Screen Parameter Name Min.Value Max.Value Resolution UnitsThis page intentionally left blank 55-56 Machine OperationThis page intentionally left blank Base Interface Cable Machine SetupAC Power Adjust Thruster Position on ColumnInitialize Home Welder Reset E-StopTurn Power on Set Tool ParametersSet Weld Process Parameters Set Vertical Travel Lower Limit PositionStarting a Weld Cycle Stopping a Weld Cycle Setup SheetDual Servo Spin Welder Setup Sheet Optimizing Performance This page intentionally left blank Material Considerations Spin Welding ProcessSurface Speed Control ParametersAverage Weld Diameter inch Rev/minSpeed SpinWeld Depth Press Axial SpeedHold Part SizeWeld Diameter Machine Peak RPM This page intentionally left blank Welder Data Export Software Installation, StartupThis page intentionally left blank Hardware Software Requirements Installation Startup, and Cable ConnectionsPart Data List Part DataPlot Data Profile GraphsFile Write Incoming DataSpin Torque Setpoint Servo and DebugWelding Process TroubleshootingThis page intentionally left blank Welding Process TroubleshootingMechanical WelderProblem Symptom Possible Cause Recommended Solution Faults Message Description Cause Possible Solution InstructionsMessage Description Cause Possible Solution Time or number of rotations Message Description Cause Possible Solution ErrorsMessage Description Cause Possible Solution This page intentionally left blank Maintenance This page intentionally left blank Maintenance AC Power CordThis page intentionally left blank Contacting Dukane This page intentionally left blank Website Contacting DukaneIdentify Equipment Ultrasonics DivisionThis page intentionally left blank Specifications This page intentionally left blank Operating Environment Tooling SpecificationsMachine Weight Power Requirements2Dual Servo Spin Welder Dimensions Welder Model & Serial Number Identification NumbersThis page intentionally left blank Appendix a Connector PinoutsThis page intentionally left blank Figure A-1Base Interface Connector Base Interface ConnectorSignal Description Function User I/O ConnectorPin Signal Description Function Slide Kit ConnectorAutomation Wiring Data Port ConnectorFigure A-5Schematic of Operate and Abort This page intentionally left blank Tooling Appendix BThis page intentionally left blank Explanation of Inertia Moment of InertiaTool and Fixture Design Appendix C Optional FeaturesThis page intentionally left blank Figure C-1Upper Tool Vacuum System Upper Tool VacuumFigure C-2 Remote Touch Screen Components Remote Touch ScreenDukane ISO