Dual Servo Spin Welder User’s Manual
The Move To button is used to rotate the tool to the value displayed in the Position (Deg..) field. After pressing this button, activate both RUN switches and wait for the value in the Jog Pos. (Deg.) field to match the Position (Deg..) value
WELD Setup
The WELD setup is the middle tab in the SETUP menu and is shown in Figure
Weld Method Selection
One of the available modes must be selected to perform a weld. Regardless of the method, the weld is considered to start at different points, depending on the Torque Trigger option setting. If Torque Trigger is OFF, the weld starts at the Trigger Position defined in the PRE- WELD tab. If Torque Trigger is ON, the weld starts when the desired spin torque threshold is exceeded (see Torque Trigger Option below).
Time Method
In this method, the weld duration is controlled by time. After choosing this method, the Weld Parameters button is used to enter the weld settings shown in Figure
Figure 5–11 WELD Main Setup Screen
Figure 5–12 Weld Parameters Screen for Time Method
Page 34 | Dukane Manual Part No. |