•Feed the work piece in the correct direction and speed. Feed the work piece into a blade, cutter, or abrasive surface against the direction of the cutting tool’s direction of rotation only. Incorrectly feeding the work piece in the same direction may cause the work piece to be thrown out at high speed.
•Never leave the tool running unattended, turn the power off. Do not leave the tool until it comes to a complete stop.
•Never start the power tool when any rotating component is in contact with the work piece.
SERVICE
•Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
•Service your power tool periodically. When cleaning a tool, be careful not to disassemble any portion of the tool since internal wires may be misplaced or pinched.
WARNING:
READ AND UNDERSTAND ALL WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. Failure to follow all instructions listed below may result in electric shock, fire and/or serious personal injury.
English
EXTENSION CORDS
Grounded tools require a three wire extension cord. Double insulated tools can use either a two or three wire extension cord. As the distance from the power supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. Refer to the table shown below to determine the required minimum wire size.
The smaller the gauge number of the wire, the greater the capacity of the cord. For example: a
Guidelines for Using Extension Cords
•If you are using an extension cord outdoors, be sure it is marked with the suffix
•Be sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified person before using it.
•Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
Recommended Minimum Wire Gauge for Extension Cords (120 Volt)
Nameplate | Extension Cord Length |
|
|
|
|
| |
Amperes | 25 Feet |
| 50 Feet | 75 Feet | 100 Feet | 150 Feet | 200 Feet |
(At Full Load) |
| ||||||
|
|
|
|
|
|
| |
18 |
| 18 | 18 | 18 | 16 | 16 | |
|
|
|
|
|
|
|
|
18 |
| 18 | 18 | 16 | 14 | 14 | |
|
|
|
|
|
|
|
|
18 |
| 18 | 16 | 14 | 12 | 12 | |
18 |
| 16 | 14 | 12 | 12 | 10 | |
|
|
|
|
|
|
|
|
18 |
| 14 | 12 | 10 | 8 | 8 | |
14 |
| 12 | 10 | 10 | 8 | 6 | |
|
|
|
|
|
|
|
|
12 |
| 10 | 8 | 8 | 6 | 6 |