Ingersoll-Rand IRN75-160K-2S, IRN37-160K-CC, IRN250-300H-2S, IRN50-200H-CC, IRN100-200H-2S Contents

Page 3

1.0 contents

contents

PAGE

 

 

1.0 contents

1

2.0 FOREWORD

2

3.0 ABBREVIATIONS & SYMBOLS

4

4.0 PURCHASE ORDER DETAILS

5

5.0 SAFETY

6

5.1 SAFETY INSTRUCTIONS

6

5.2 SAFETY PRECAUTIONS

6

5.3 TEXT DECALS

9

5.4 GRAPHIC FORM AND MEANING OF ISO

SYMBOLS

13

6.0 RECEIPT / HANDLING

18

6.1 RECEIPT

18

6.2 UNPACKING AND HANDLING

18

7.0 INSTALLATION

19

7.1 LOCATION IN PLANT

19

7.2DISCHARGE AND CONDENSATE PIPING 20

7.3 ELECTRICAL

21

7.4 WATERCOOLED UNITS

23

7.5 SEA WATERCOOLED UNITS (SELECTED

UNITS ONLY)

25

7.6 OUTDOOR SHELTERED INSTALLATION26

8.0 GENERAL INFORMATION

27

8.1 TECHNICAL INFORMATION

27

8.2 INSTALLATION DRAWING

33

8.3 PROCESS AND INSTRUMENTATION

 

DIAGRAM

42

8.4 ELECTRICAL SCHEMATIC

50

8.5 GENERAL DESCRIPTION

64

9.0 OPERATING INSTRUCTIONS

65

9.1 BASIC OPERATION

65

9.2 INTELLISYS CONTROLS

67

9.3 DISPLAY SCREEN

68

9.4 CURRENT STATUS SCREEN

69

9.5 MAIN MENU

70

contents

PAGE

 

 

 

9.6 OPERATOR SETPOINTS

71

9.7 OPTIONS

73

9.8 SENSOR CALIBRATION

74

9.9 ALARM HISTORY

75

9.10 CLOCK FUNCTIONS

75

9.11 ENERGY STATUS MESSAGES

76

9.12 WARNINGS

77

9.13 SERVICE WARNINGS

77

9.14 INITIAL CHECK ALARMS:

77

9.15 ALARMS

78

10.0 MAINTENANCE

79

10.1 MAINTENANCE PROMPTS

79

10.2 MAINTENANCE CHART

80

10.3 MAINTENANCE PROCEDURES

81

10.4 ROUTINE MAINTENANCE

83

11.0 FAULT FINDING

91

IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

Image 3
Contents Operation and Maintenance Manual AIR Compressor Group Bonded Warranty & Registered Start UP Contents Foreword If in Doubt Consult SupervisionSomer FOREWORD F.C Abbreviations & SymbolsEnergy recovery system ERSPurchase Order Details Rotary Screw AIR CompressorThis unit was purchased from Safety General InformationCompressed air Electrical MaterialsAvoid INGESTION, Skin Contact Inhalation of Fumes TransportCoolant disposal Condensate disposalDischarge air Text DecalsLift here 39540257 Rev RotationCondensate Drain Electrical power inlet Prohibition / Mandatory Information / Instructions Safety Graphic Form and Meaning of ISO SymbolsDo not stand on any service valve or Safety Coolant Separator Pressure AIR Discharge Belt Tension Filter Motor Lubrication Unpacking and Handling Receipt / HandlingReceipt Ingersoll Rand CompanyEnsure that the correct tie down points are used InstallationLocation in Plant For technical information see sectionInstallation Discharge and Condensate Piping Installation Electrical Installation Very Important Fuse TypeExample of voltage imbalance calculation 50F 70F Adjusting the Aftercooler Trim ValveCooling Water Piping Model Minimum cooling water requirement vs RangeWater quality recommendations Installation SEA Watercooled Units Selected Units only Orifice diameter in mmPsi Outdoor Sheltered Installation Technical INFORMATION-SINGLE Stage General InformationFlow at 7.5 Barg m3/min Minimum ambient temperature C F Weight Kg lbsCooling clean water flow l/min US 51/38 95/46 Sound pressure level dBAMax fuse size @ 550V − 575V a Cooling clean water flow l/min US 84/65 95/72Max fuse size @ 380V − 415V a Max fuse size @ 440V − 480V aN132K N160K N200H General Information Technical Information − TWO Stage 1527 5933Flow at 100 psig cfm 1100 1690KEY Installation DRAWING−N37/45K−CC & N50/60H−CC − Air CooledInstallation DRAWING− N37/45K−CC & N50/60H−CC − Water Cooled Installation Drawing − N55/75K−CC & N75/100H−CC − Air Cooled Installation DRAWING−N55/75K−CC & N75/100H−CC−Water Cooled General Information General Information General Information General Information KEY 22381206 Revision B Equipment downstream of compressor Stage only 23128994 Revision aAir/coolant Coolant Condensate Cooling water W.C. only 22099006 Revision C General Information 22402135 Revision C Process and Instrumentation Diagram N250−300H TWO StagePiping legend Stop FD Wiring Schematic N37K − N45K-CC / N50-60h−cc a/c blower vfdNumbers Function Wire color WiresLabel Description Wiring schematic n55-75k-cc / n75-100h-cc a/c Blower vfdSS1-3 Wires Numbers Function Wire colorSgne Wiring schematic n37/45k-cc/n50/60h-cc w/cColor 23131345 Revision a Wiring schematic n55-75k-cc / n75-100h-cc W/c4ATT SENSOR, Package AIR Discharge Temperature 4CTT Wiring schematic n75-160k-cc / n125-200h-cc A/c 22093058Revision M SGNe F10Revision E Wiring schematic n75-160k-cc / n125-200h-cc W/c4SV VALVE, Water Stop 6APT 380-480V SG-Ne Wiring schematic n250-300H4ATT SENSOR, Package AIR Discharge Temperature 6APT General Information General Description Basic Operation Operating InstructionsStopping the machine in an emergency Arrows Intellisys ControlsMain Menu Display ScreenCurrent Status items Current Status ScreenReady to Start Main MenuOperator Setpoints Operator Setpoints Default MIN MAX Step UnitCondensate Interval Selection MIN MAX OptionsScheduled start Sensor CalibrationClock Functions Alarm HistoryEnergy Status Messages Initial Check Alarms Service WarningsAlarm Main Menu AlarmsMaintenance Ultra Coolant Maintenance Procedures Prior to attempting any maintenance work, ensure that− Adding coolant Prior to starting Coolant level checking procedureDrain sequence for N250/300H−2S Coolant filter change procedureSeparator element checking procedure Separator element change procedureSeparator tank / Pressure system Separator element change procedure for N250/ 300H−2SScavenge screen clean/check procedure Start the compressor and check for leaks and coolant levelBlower motor Re−Grease Air filter change procedureAir filter change procedure N250/300H−2S Aircooled Cooler CleaningN50/100H N37/75K Aftercooler Watercooled Cooler CleaningHigh Airend Temperature Sensor checking procedure Coolant CoolersMoisture Separator Check / Cleaning Blower / fan Motor Bearing Maintenance Stored unitsMotor cowl cleaning N75−160 units only Drive Box Filter Removal / ReplacementNo Loss Drain Trap where fitted Check / Cleaning Coolant Sampling ProcedureFluid and Vibration Monitoring Compressor will not No power supply to package Fault FindingGeneral Faults Symptom Fault RemedyCheck and modify settings With correct coolant Or not sealing correctlySee above With coolant’Remove blockage, repair or replace damaged Pressure transducer Fault Cause RemedyDrive Faults Fault Cause ActionIndicated on the INTELhYS Controller