Ingersoll-Rand IRN250-300H-2S manual Abbreviations & Symbols, Ers, Energy recovery system, F.C

Page 6

3.0ABBREVIATIONS & SYMBOLS

####Contact Ingersoll Rand for serial number

−>####

Up to Serial No.

####−>

From Serial No.

*

Not illustrated

Option

NR

Not required

AR

As required

SM

Sitemaster/Sitepack

HA

High ambient machine

WC

Watercooled machine

AC

Aircooled machine

ERS

Energy recovery system

T.E.F.C.

Totally enclosed fan cooled motor (IP54)

O.D.P.

Open drip proof (motor)

ppm

parts per million

cs

Czech

da

Danish

de

German

el

Greek

en

English

es

Spanish

et

Estonian

fi

Finnish

fr

French

hu

Hungarian

it

Italian

lt

Lithuanian

lv

Latvian, Lettish

mt

Maltese

nl

Dutch

no

Norwegian

pl

Polish

pt

Portuguese

sk

Slovak

sl

Slovenian

sv

Swedish

zh

Chinese



IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

 

Image 6
Contents Operation and Maintenance Manual AIR Compressor Group Bonded Warranty & Registered Start UP Contents Foreword If in Doubt Consult SupervisionSomer FOREWORD ERS Abbreviations & SymbolsEnergy recovery system F.CPurchase Order Details Rotary Screw AIR CompressorThis unit was purchased from Safety General InformationCompressed air Transport MaterialsAvoid INGESTION, Skin Contact Inhalation of Fumes ElectricalCondensate disposal Coolant disposalText Decals Discharge airLift here Rotation 39540257 RevCondensate Drain Electrical power inlet Safety Graphic Form and Meaning of ISO Symbols Prohibition / Mandatory Information / InstructionsDo not stand on any service valve or Safety Coolant Separator Pressure AIR Discharge Belt Tension Filter Motor Lubrication Ingersoll Rand Company Receipt / HandlingReceipt Unpacking and HandlingFor technical information see section InstallationLocation in Plant Ensure that the correct tie down points are usedInstallation Discharge and Condensate Piping Installation Electrical Installation Very Important Fuse TypeExample of voltage imbalance calculation Model Minimum cooling water requirement vs Range Adjusting the Aftercooler Trim ValveCooling Water Piping 50F 70FWater quality recommendations Installation SEA Watercooled Units Selected Units only Orifice diameter in mmPsi Outdoor Sheltered Installation General Information Technical INFORMATION-SINGLE StageSound pressure level dBA Minimum ambient temperature C F Weight Kg lbsCooling clean water flow l/min US 51/38 95/46 Flow at 7.5 Barg m3/minMax fuse size @ 440V − 480V a Cooling clean water flow l/min US 84/65 95/72Max fuse size @ 380V − 415V a Max fuse size @ 550V − 575V aN132K N160K N200H General Information Technical Information − TWO Stage 1690 5933Flow at 100 psig cfm 1100 1527Installation DRAWING−N37/45K−CC & N50/60H−CC − Air Cooled KEYInstallation DRAWING− N37/45K−CC & N50/60H−CC − Water Cooled Installation Drawing − N55/75K−CC & N75/100H−CC − Air Cooled Installation DRAWING−N55/75K−CC & N75/100H−CC−Water Cooled General Information General Information General Information General Information KEY 22381206 Revision B Equipment downstream of compressor 23128994 Revision a Stage onlyAir/coolant Coolant Condensate Cooling water W.C. only 22099006 Revision C General Information Process and Instrumentation Diagram N250−300H TWO Stage 22402135 Revision CPiping legend Wiring Schematic N37K − N45K-CC / N50-60h−cc a/c blower vfd Stop FDWires Numbers Function Wire colorWiring schematic n55-75k-cc / n75-100h-cc a/c Blower vfd Label DescriptionWires Numbers Function Wire color SS1-3Wiring schematic n37/45k-cc/n50/60h-cc w/c SgneColor Wiring schematic n55-75k-cc / n75-100h-cc W/c 23131345 Revision a4ATT SENSOR, Package AIR Discharge Temperature 4CTT Wiring schematic n75-160k-cc / n125-200h-cc A/c 22093058Revision M F10 SGNeWiring schematic n75-160k-cc / n125-200h-cc W/c Revision E4SV VALVE, Water Stop 6APT Wiring schematic n250-300H 380-480V SG-Ne4ATT SENSOR, Package AIR Discharge Temperature 6APT General Information General Description Operating Instructions Basic OperationStopping the machine in an emergency Intellisys Controls ArrowsDisplay Screen Main MenuCurrent Status Screen Current Status itemsMain Menu Ready to StartOperator Setpoints Default MIN MAX Step Unit Operator SetpointsCondensate Interval Options Selection MIN MAXSensor Calibration Scheduled startAlarm History Clock FunctionsEnergy Status Messages Service Warnings Initial Check AlarmsAlarms Alarm Main MenuMaintenance Ultra Coolant Maintenance Procedures Prior to attempting any maintenance work, ensure that− Prior to starting Coolant level checking procedure Adding coolantSeparator element change procedure Coolant filter change procedureSeparator element checking procedure Drain sequence for N250/300H−2SStart the compressor and check for leaks and coolant level Separator element change procedure for N250/ 300H−2SScavenge screen clean/check procedure Separator tank / Pressure systemAircooled Cooler Cleaning Air filter change procedureAir filter change procedure N250/300H−2S Blower motor Re−GreaseN50/100H N37/75K Coolant Coolers Watercooled Cooler CleaningHigh Airend Temperature Sensor checking procedure AftercoolerDrive Box Filter Removal / Replacement Blower / fan Motor Bearing Maintenance Stored unitsMotor cowl cleaning N75−160 units only Moisture Separator Check / CleaningNo Loss Drain Trap where fitted Check / Cleaning Coolant Sampling ProcedureFluid and Vibration Monitoring Symptom Fault Remedy Fault FindingGeneral Faults Compressor will not No power supply to packageCheck and modify settings Or not sealing correctly With correct coolantSee above With coolant’Remove blockage, repair or replace damaged Fault Cause Remedy Pressure transducerDrive Faults Fault Cause ActionIndicated on the INTELhYS Controller