8.0 GENERAL INFORMATION
KEY
4SV | VALVE, WATER STOP SOLENOID (W/C ONLY) |
6APT | TRANSDUCER, SUMP AIR PRESSURE, DRY SIDE |
9APT | TRANSMITTER, REMOTE AIR PRESSURE |
| (OPTIONAL) |
9SV | VALVE, CONDENSATE DRAIN |
11SV | VALVE, |
AT | AUTOTRANSFORMER (IF FITTED) |
AW1 | AUXILIARY WARNING 1 |
AW2 | AUXILIARY WARNING 2 |
BP | BACKPLATE |
CCAPACITOR
CAB CABINET
CDE | CONDENSATE DRAIN ERROR |
CDV | CONDENSATE DRAIN VALVE (IF FITTED) |
CFO | COMMON FAULT OUTPUT |
CK | CHOKE |
EXC | EXTERNAL COMMUNICATIONS |
DR | DRIVE |
DVF | FAN, DRIVE BOX VENTILATION |
EB | EARTH BAR |
ES | SWITCH, EMERGENCY STOP |
FD | DRIVE, BLOWER |
FM | MOTOR, BLOWER |
GND | GROUND |
HTR1 | HEATER, SPACER 25 WATTS |
HTR2 | HEATER, SPACER 25 WATTS |
K1 | RELAY, RUN |
K2 | RELAY, FAULT |
KM1 | CONTACTOR, MAIN MOTOR |
KM5 | CONTACTOR, DRIVE VENTILATION FAN |
MCB1 | BREAKER, MINIATURE CIRCUIT, TRANSFORMER |
MCB2 | BREAKER, MINIATURE CIRCUIT, DVF |
MCB3 | BREAKER, MINIATURE CIRCUIT, CONTROL |
| CIRCUITS |
MCB4 | BREAKER, MINIATURE CIRCUIT, VFD SUPPLY |
MCB5 | BREAKER, MINATURE CIRCUIT, PSU |
MCB9 | BREAKER, MINIATURE CIRCUIT, HEATERS |
MF | MAINS FILTER (IF FITTED) |
MM | MOTOR, MAIN |
MMS | BREAKER, FAN MOTOR |
OPT | OPTIONAL |
OV | ZERO VOLTAGE |
PE | PROTECTED EARTH |
PORO | POWER OUTAGE RESTART OPTION (OPTIONAL) |
PSU | POWER SUPPLY UNIT |
RFI | FILTER, RADIO FREQUENCY INTERFERENCE |
RSP | REMOTE STOP |
RST | REMOTE START |
SGNE | CONTROLLER, INTELLISYS |
SL | SERIAL LINK |
| RELAY, SOLID STATE |
ST | SERVICE TOOL |
T1 | TRANSFORMER, CONTROL |
TH | THERMOSTAT |
TRR | TRUE RUNNING |
WR | GENERAL WARNING |
COLORS |
|
BLK | BLACK |
BLU | BLUE |
BRO | BROWN |
GRE | GREEN |
PIN | PINK |
RED | RED |
SCR | SCREEN |
VIO | VIOLET |
WHI | WHITE |
YEL | YELLOW |
Wires
Numbers | Function | Wire color |
1−99 | Power | Black |
100−199 | AC Control | Red |
200−299 | DC Control | Blue |
300−399 | Auxiliary | Orange |
NOTES:
1.FACTORY SUPPLIED AS SHOWN BY CONNECTION TO OUTPUT OF CONTROL TRANSFORMER T1. WIRE NUMBER
100& 121.
2.ALTERNATIVELY THE SUPPLY MAY BE TAKEN FROM AN
INDEPENDENT SOURCE: IN THAT CASE, FACTORY SUPPLIED CONNECTION MUST BE DISCONNECTED.
3. ENSURE PARALLEL CONNECTION OF HEATERS.
NOTES:
1.CONNECTIONS FOR USE ON 200/230V SYSTEMS. THE SUPPLY IS INDEPENDENT OF THE MAIN COMPRESSOR. THE CUSTOMER MUST PROVIDE AN ISOLATOR / DISCONNECT SWITCH ADJACENT TO THE MACHINE FOR THIS SUPPLY. IN THAT CASE, FACTORY SUPPLIED CONNECTION MUST BE DISCONNECTED.
2.ENSURE SERIES CONNECTION OF HEATERS.
IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S | 53 |
http://air.irco.com |
|