8.0 GENERAL INFORMATION
KEY
1Air discharge
2Compressor
3Air filter
4Vacuum switch 1VAC
5Cooler, air
6Cooler, coolant
7Condensate discharge
8Coolant filter
9Pressure switch, coolant filter 1DPS
10Drain valve, coolant
11Temperature switch 1ATS
12Air inlet/adaptor
13Coolant stop solenoid valve 5SV
14Minimum pressure check valve
15Moisture separator
16Pressure transducer 4APT
17Pressure relief valve
18Scavenge filter / orifice / check
19Separator tank (primary/secondary)
20Oil temperature control valve
21Temperature transducer 2ATT
223SV blowdown solenoid valve
23Drive motor
24Blower motor
25Cooling air blower
26Cooling water inlet (W.C. only)
27Cooling water outlet (W.C. only)
28Pressure transducer 3APT
29Pressure transducer 6APT
30Dryer (customer supply equipment)
31Line filters (customer equipment)
32Receivers (customer equipment)
33Dryer AUX warning
34Line filter AUX warning
35Receiver trap AUX warning
36Remote pressure transducer 9APT (optional)
37Water stop valve 4SV (W.C. only)
38Typical customer downstream air treatment
39Anti − condensation valve 11SV
40Cooling air exhaust box
41Package discharge temperature transducer 4ATT
42Injection temperature, transducer 2CTT
43Orifice, seal scavenge air supply
44Seal scavenge line
45Temperature sensor 1ATT
46Electronic drain trap
47Interstage pressure relief valve. 2 stage.
48Interstage pressure transducer. 2 stage
49Element, separator
50Valve, aftercooler trim (W.C. only)
51Valve, airend discharge temperature control (W.C. only)
52Airend discharge check valve.
Piping legend
Air/coolant
Air
Coolant
Condensate
Cooling water (W.C. only)
Compressor enclosure Sensor connection
Equipment downstream of compressor
IRN37 - 160K - CC & IRN50 - 200H & IRN75 - 160K - 2S & IRN - 100 - 200H - 2S & IRN 250 - 300H - 2S | 49 |
http://air.irco.com |
|