8.0 GENERAL INFORMATION
KEY
A2” NPT Air discharge (Female) 60Hz units (N100H−N150H)
2” BSP Air discharge (Female) 50Hz units (N75K−N110K)
2 1/2” NPT Air discharge (Female) 60Hz units (N200H)
2 1/2” BSP Air discharge (Female) 50Hz units (N132K and N160K units)
BElectrical inlet − Ø75mm (3”)
Ø64mm 575V (Option)
C0.38“ NPT (Female)
Note: Pipe condensate drain lines separately to an open drain due to differences in drain pressures. Use drain lines at least as large as the connection. Read operations manual and check local regulations
DCooling airflow
EExhaust airflow
FCabinet cooling airflow
G4 x Ø 13.0mm (0,5”)
Compressor should be bolted to the floor with four M10 (0.38”) bolts using holes shown. Seal base to floor with cork or rubber.
HINTELLISYS Controller
J1.5” NPT Water inlet (Female) 60Hz units 1.5” BSP Water inlet (Female) 50Hz units
K1.5” NPT Water outlet (Female) 60Hz units 1.5” BSP Water outlet (Female) 50Hz units
URight
VBottom
WFront
X−X Section through X−X
YRear view
ZPlan view
38IRN37 - 160K - CC & IRN50 - 200H