8.0 GENERAL INFORMATION

N132K

N160K

N200H

General

Sound pressure level dB(A) *

75

75

75

Maximum ambient temperature ° C (° F)

46 (115)

46 (115)

46 (115)

Minimum ambient temperature ° C (° F)

1.7 (35)

1.7 (35)

1.7 (35)

Weight Kg (lbs)

3175 (6985)

3175 (6985)

3175 (6985)

Maximum pressure barg (psig)

10 (145)

10 (145)

10 (145)

Minimum pressure barg (psig)

4.5 (65)

4.5 (65)

4.5 (65)

Coolant capacity litres (US gal)

91 (24)

91 (24)

91 (24)

HAT switch setting ° C (° F)

120 (248)

120 (248)

120 (248)

Performance **

 

 

 

Flow at 7.5 Barg (m3/min)

23.5

28.0

Flow at 8.5 Barg (m3/min)

22.3

26.0

Flow at 10 Barg (m3/min)

21.0

25.0

Flow at 100 psig (cfm)

993

Flow at 125 psig (cfm)

892

Flow at 140 psig (cfm)

819

Air Cooling System

 

 

 

Cooling air flow m3/min (cfm)

382 (13500)

382 (13500)

382 (13500)

Maximum ΔP in air ducts Pa (inch WG)

124 (0.5)

124 (0.5)

124 (0.5)

Compressed air outlet ΔT ° C (° F)

8 (15)

8 (15)

8 (15)

Water Cooling System

 

 

 

Cooling (clean) water flow l/min (US gallon/

110/87

125/106

125/106

min) @ 10° C (50° F) / 32° C (90° F)

(29/23)

(33/28)

(33/28)

 

Maximum ΔP in air ducts Pa (inch WG)

62 (0.25)

62 (0.25)

62 (0.25)

Compressed air outlet ΔT ° C (° F)

14 (25)

14 (25)

14 (25)

Main Power Circuit A/C (W/C) ***

 

 

 

Package full load current at 400V (A) **

251 (239)

301(289)

Package full load current at 460V (A) **

255 (245)

Package full load current at 575V (A) **

210 (202)

Max fuse size @ 380V − 415V (A)

350

450

Max fuse size @ 440V − 480V (A)

350

Max fuse size @ 550V − 575V (A)

300

Fuse type

Fast acting class J, T or semiconductor type, current limiting

 

interrupt rating 200, 000 Amps RMS SYM.

Heater Circuit

 

 

 

110V Single Phase Rating (A)

4

4

4

 

 

 

 

230V Single Phase Rating (A)

4

4

4

Fuse type

 

General purpose

 

*In accordance with PNEUROP PN8NTC2.3

**Tolerances in accordance with ISO 1217

***Always apply local electrical codes for sizing cables and fusing. In the absence of local codes the minimum cable size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)

30IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

Image 32
Contents Operation and Maintenance Manual AIR Compressor Group Bonded Warranty & Registered Start UP Contents Somer ForewordIf in Doubt Consult Supervision FOREWORD Abbreviations & Symbols Energy recovery systemERS F.CThis unit was purchased from Purchase Order DetailsRotary Screw AIR Compressor Compressed air SafetyGeneral Information Materials Avoid INGESTION, Skin Contact Inhalation of FumesTransport ElectricalCondensate disposal Coolant disposalText Decals Discharge airLift here Rotation 39540257 RevCondensate Drain Electrical power inlet Safety Graphic Form and Meaning of ISO Symbols Prohibition / Mandatory Information / InstructionsDo not stand on any service valve or Safety Coolant Separator Pressure AIR Discharge Belt Tension Filter Motor Lubrication Receipt / Handling ReceiptIngersoll Rand Company Unpacking and HandlingInstallation Location in PlantFor technical information see section Ensure that the correct tie down points are usedInstallation Discharge and Condensate Piping Installation Electrical Example of voltage imbalance calculation Installation Very ImportantFuse Type Adjusting the Aftercooler Trim Valve Cooling Water PipingModel Minimum cooling water requirement vs Range 50F 70FWater quality recommendations Psi Installation SEA Watercooled Units Selected Units onlyOrifice diameter in mm Outdoor Sheltered Installation General Information Technical INFORMATION-SINGLE StageMinimum ambient temperature C F Weight Kg lbs Cooling clean water flow l/min US 51/38 95/46Sound pressure level dBA Flow at 7.5 Barg m3/minCooling clean water flow l/min US 84/65 95/72 Max fuse size @ 380V − 415V aMax fuse size @ 440V − 480V a Max fuse size @ 550V − 575V aN132K N160K N200H General Information Technical Information − TWO Stage 5933 Flow at 100 psig cfm 11001690 1527Installation DRAWING−N37/45K−CC & N50/60H−CC − Air Cooled KEYInstallation DRAWING− N37/45K−CC & N50/60H−CC − Water Cooled Installation Drawing − N55/75K−CC & N75/100H−CC − Air Cooled Installation DRAWING−N55/75K−CC & N75/100H−CC−Water Cooled General Information General Information General Information General Information KEY 22381206 Revision B Equipment downstream of compressor 23128994 Revision a Stage onlyAir/coolant Coolant Condensate Cooling water W.C. only 22099006 Revision C General Information Process and Instrumentation Diagram N250−300H TWO Stage 22402135 Revision CPiping legend Wiring Schematic N37K − N45K-CC / N50-60h−cc a/c blower vfd Stop FDWires Numbers Function Wire colorWiring schematic n55-75k-cc / n75-100h-cc a/c Blower vfd Label DescriptionWires Numbers Function Wire color SS1-3Wiring schematic n37/45k-cc/n50/60h-cc w/c SgneColor Wiring schematic n55-75k-cc / n75-100h-cc W/c 23131345 Revision a4ATT SENSOR, Package AIR Discharge Temperature 4CTT Revision M Wiring schematic n75-160k-cc / n125-200h-cc A/c22093058 F10 SGNeWiring schematic n75-160k-cc / n125-200h-cc W/c Revision E4SV VALVE, Water Stop 6APT Wiring schematic n250-300H 380-480V SG-Ne4ATT SENSOR, Package AIR Discharge Temperature 6APT General Information General Description Operating Instructions Basic OperationStopping the machine in an emergency Intellisys Controls ArrowsDisplay Screen Main MenuCurrent Status Screen Current Status itemsMain Menu Ready to StartOperator Setpoints Default MIN MAX Step Unit Operator SetpointsCondensate Interval Options Selection MIN MAXSensor Calibration Scheduled startAlarm History Clock FunctionsEnergy Status Messages Service Warnings Initial Check AlarmsAlarms Alarm Main MenuMaintenance Ultra Coolant Maintenance Procedures Prior to attempting any maintenance work, ensure that− Prior to starting Coolant level checking procedure Adding coolantCoolant filter change procedure Separator element checking procedureSeparator element change procedure Drain sequence for N250/300H−2SSeparator element change procedure for N250/ 300H−2S Scavenge screen clean/check procedureStart the compressor and check for leaks and coolant level Separator tank / Pressure systemAir filter change procedure Air filter change procedure N250/300H−2SAircooled Cooler Cleaning Blower motor Re−GreaseN50/100H N37/75K Watercooled Cooler Cleaning High Airend Temperature Sensor checking procedureCoolant Coolers AftercoolerBlower / fan Motor Bearing Maintenance Stored units Motor cowl cleaning N75−160 units onlyDrive Box Filter Removal / Replacement Moisture Separator Check / CleaningFluid and Vibration Monitoring No Loss Drain Trap where fitted Check / CleaningCoolant Sampling Procedure Fault Finding General FaultsSymptom Fault Remedy Compressor will not No power supply to packageCheck and modify settings Or not sealing correctly With correct coolantRemove blockage, repair or replace damaged See aboveWith coolant’ Fault Cause Remedy Pressure transducerIndicated on the INTELhYS Controller Drive FaultsFault Cause Action