Ingersoll-Rand IRN50-200H-CC, IRN37-160K-CC, IRN250-300H-2S, IRN75-160K-2S manual Ultra Coolant

Page 82

10.0 MAINTENANCE

10.2 MAINTENANCE CHART

The MAINTENANCE CHART indicates the various components and the intervals when maintenance has to take place. Where a service interval is stated in both hours and months, it is the sooner of the two intervals that must be adhered to. Coolant capacities etc can be found in the GENERAL INFORMATION section of this manual. Note that any Local or National codes that require specific maintenance that exceeds the requirements of this section must be adhered to.

 

 

 

 

Maintenance Schedule

 

 

 

 

 

 

 

Hours:

150

 

500

2000

4000

8000

 

 

(1st time

 

1000

6000

12000

16000

 

 

only)

 

 

 

 

 

 

 

 

 

1500

10000

20000

 

 

Daily

 

 

2500

14000

 

 

 

 

 

 

3000

18000

 

 

Coolant filter

 

Change

 

 

Change

Change

Change

 

 

 

 

 

 

 

 

Air filter **

 

 

 

 

Check

Change

Change

 

 

 

 

 

pressure

 

 

Separator element ***

 

 

 

 

Check

Change

Change

 

 

 

 

 

pressure

 

 

ULTRA COOLANT*

Check

 

 

 

Sample

Sample

Change

Power Drive Module filter *

 

 

 

Check

Change

Change

Change

Scavenge screen **

 

 

 

 

Check /

Check /

Check /

 

 

 

 

 

clean

clean

clean

Hoses ***

 

 

 

 

 

Check /

Check /

 

 

 

 

 

 

clean

clean

High Air Temperature sensor

 

 

 

Check

Check

Check

Check

 

 

 

 

 

 

 

 

Pressure relief valve

 

 

 

 

Check

Check

Check

Cooler Core(s)

 

 

 

Check /

Check /

Check /

Check /

 

 

 

 

clean

clean

clean

clean

Moisture separator

 

 

 

Check /

Check /

Check /

Check /

 

 

 

 

clean

clean

clean

clean

Motor cowl

 

 

 

Check /

Check /

Check /

Check /

 

 

 

 

clean

clean

clean

clean

Vibration Analysis

 

 

 

 

Analysis

Analysis

Analysis

Coolant Analysis

 

 

 

 

Analysis

Analysis

Analysis

 

 

 

 

 

 

 

 

Food Grade Coolant *

 

 

 

Analysis at every 500

 

 

 

 

 

 

Change at every 1000

 

 

 

 

 

 

 

 

 

 

Blower Motor / Fan Motor

 

 

 

 

 

Regrease

Regrease

If the compressor is run less than 4,000 hours per year,

 

 

 

 

 

HPM 250L motor Regrease at 2000hrs and 4000hrs N250/300H-2S only

*Maintain every 6 months

**Maintain every year

***Maintain every 2 years

80IRN37 - 160K - CC & IRN50 - 200H -CC & IRN75 - 160K - 2S & IRN100 - 200H - 2S & IRN 250 - 300H - 2S

http://air.irco.com

Image 82
Contents Operation and Maintenance Manual AIR Compressor Group Bonded Warranty & Registered Start UP Contents If in Doubt Consult Supervision ForewordSomer FOREWORD ERS Abbreviations & SymbolsEnergy recovery system F.CRotary Screw AIR Compressor Purchase Order DetailsThis unit was purchased from General Information SafetyCompressed air Transport MaterialsAvoid INGESTION, Skin Contact Inhalation of Fumes ElectricalCondensate disposal Coolant disposalText Decals Discharge airLift here Rotation 39540257 RevCondensate Drain Electrical power inlet Safety Graphic Form and Meaning of ISO Symbols Prohibition / Mandatory Information / InstructionsDo not stand on any service valve or Safety Coolant Separator Pressure AIR Discharge Belt Tension Filter Motor Lubrication Ingersoll Rand Company Receipt / HandlingReceipt Unpacking and HandlingFor technical information see section InstallationLocation in Plant Ensure that the correct tie down points are usedInstallation Discharge and Condensate Piping Installation Electrical Fuse Type Installation Very ImportantExample of voltage imbalance calculation Model Minimum cooling water requirement vs Range Adjusting the Aftercooler Trim ValveCooling Water Piping 50F 70FWater quality recommendations Orifice diameter in mm Installation SEA Watercooled Units Selected Units onlyPsi Outdoor Sheltered Installation General Information Technical INFORMATION-SINGLE StageSound pressure level dBA Minimum ambient temperature C F Weight Kg lbsCooling clean water flow l/min US 51/38 95/46 Flow at 7.5 Barg m3/minMax fuse size @ 440V − 480V a Cooling clean water flow l/min US 84/65 95/72Max fuse size @ 380V − 415V a Max fuse size @ 550V − 575V aN132K N160K N200H General Information Technical Information − TWO Stage 1690 5933Flow at 100 psig cfm 1100 1527Installation DRAWING−N37/45K−CC & N50/60H−CC − Air Cooled KEYInstallation DRAWING− N37/45K−CC & N50/60H−CC − Water Cooled Installation Drawing − N55/75K−CC & N75/100H−CC − Air Cooled Installation DRAWING−N55/75K−CC & N75/100H−CC−Water Cooled General Information General Information General Information General Information KEY 22381206 Revision B Equipment downstream of compressor 23128994 Revision a Stage onlyAir/coolant Coolant Condensate Cooling water W.C. only 22099006 Revision C General Information Process and Instrumentation Diagram N250−300H TWO Stage 22402135 Revision CPiping legend Wiring Schematic N37K − N45K-CC / N50-60h−cc a/c blower vfd Stop FDWires Numbers Function Wire colorWiring schematic n55-75k-cc / n75-100h-cc a/c Blower vfd Label DescriptionWires Numbers Function Wire color SS1-3Wiring schematic n37/45k-cc/n50/60h-cc w/c SgneColor Wiring schematic n55-75k-cc / n75-100h-cc W/c 23131345 Revision a4ATT SENSOR, Package AIR Discharge Temperature 4CTT 22093058 Wiring schematic n75-160k-cc / n125-200h-cc A/cRevision M F10 SGNeWiring schematic n75-160k-cc / n125-200h-cc W/c Revision E4SV VALVE, Water Stop 6APT Wiring schematic n250-300H 380-480V SG-Ne4ATT SENSOR, Package AIR Discharge Temperature 6APT General Information General Description Operating Instructions Basic OperationStopping the machine in an emergency Intellisys Controls ArrowsDisplay Screen Main MenuCurrent Status Screen Current Status itemsMain Menu Ready to StartOperator Setpoints Default MIN MAX Step Unit Operator SetpointsCondensate Interval Options Selection MIN MAXSensor Calibration Scheduled startAlarm History Clock FunctionsEnergy Status Messages Service Warnings Initial Check AlarmsAlarms Alarm Main MenuMaintenance Ultra Coolant Maintenance Procedures Prior to attempting any maintenance work, ensure that− Prior to starting Coolant level checking procedure Adding coolantSeparator element change procedure Coolant filter change procedureSeparator element checking procedure Drain sequence for N250/300H−2SStart the compressor and check for leaks and coolant level Separator element change procedure for N250/ 300H−2SScavenge screen clean/check procedure Separator tank / Pressure systemAircooled Cooler Cleaning Air filter change procedureAir filter change procedure N250/300H−2S Blower motor Re−GreaseN50/100H N37/75K Coolant Coolers Watercooled Cooler CleaningHigh Airend Temperature Sensor checking procedure AftercoolerDrive Box Filter Removal / Replacement Blower / fan Motor Bearing Maintenance Stored unitsMotor cowl cleaning N75−160 units only Moisture Separator Check / CleaningCoolant Sampling Procedure No Loss Drain Trap where fitted Check / CleaningFluid and Vibration Monitoring Symptom Fault Remedy Fault FindingGeneral Faults Compressor will not No power supply to packageCheck and modify settings Or not sealing correctly With correct coolantWith coolant’ See aboveRemove blockage, repair or replace damaged Fault Cause Remedy Pressure transducerFault Cause Action Drive FaultsIndicated on the INTELhYS Controller