Sanyo KS3082, KS3682 LED Clean Mode, Unoccupied Mode, Cooling Mode, Unoccupied Indication Status

Page 11

01_KS3682_EN.fm Page 11 Friday, February 12, 2010 12:26 PM

7. LED CLEAN Mode

In LED CLEAN mode, a UV anti-bacterial unit (including a LED CLEAN lamp and anti-bacterial filter) in the indoor unit is used during DRY, COOL, or FAN operation to remove bacteria from air blown from the air conditioner.

Press the LED CLEAN button while operation.

The mark appears in the display.

To cancel, press the LED CLEAN button again.

When the LED CLEAN button is pressed, the UV anti-bacterial unit operates for one hour and cleans air blown from the air conditioner.

NOTE

Pressing the MODE selector button cancels LED CLEAN mode.

Do not open the front panel while the LED CLEAN lamp on the display is on.

Depending on the room brightness, light from the LED CLEAN lamp may reflect inside the air conditioner and be visible. This is not a malfunction.

Unoccupied Indication

Unoccupied

Unoccupied

Status

Function

Indication

 

 

 

 

OFF

no display

The unoccupied function is not set.

 

 

 

 

 

The unoccupied function is now

 

 

being set, and under Cooling

 

flashing

operation.

ON

 

 

 

 

Although the unoccupied function is

 

 

 

 

set, not under Cooling operation.

 

lighting

 

 

 

 

NOTE

Even if Unoccupied Mode is ON, it will be disabled if the air conditioner is in operation.

Unoccupied Function can be set and released through all operational modes, regardless of whether the air conditioner is operating or not.

If the Unoccupied Function is ON and the remote control unit is used to turn the air conditioner OFF (including OFF TIMER), the air conditioner will turn off, but depending on the room temperature, Cooling Operation will automatically begin.

When the Unoccupied Function is in operation and the ON/OFF operation button is pressed, operation will restart based on the settings input before the air conditioner was turned off.

In Cooling Mode: ( )

(1)When the room temperature rises above 89°F, Cooling Operation will begin.

(2)When the room temperature drops below 82°F, Cooling Operation will stop.

The above actions will repeat so that the room temperature is maintained at about 86°F.

8. UNOCCUPIED Mode

Room

Temperature (°F)(1)

89

86

82(2)

Cooling Cooling

starts stops

Time

Unoccupied mode is used to prevent the room temperature from increasing too much when no one is in the room, and operate automatically to save energy.

Press the UNOCCUPIED button. The mark appears in the display.

To release the unoccupied function, press the UNOCCUPIED button again.

Unoccupied Mode triggers Cooling Operation in response to the room temperature, but when this happens, the remote control unit will continue to display the Operation mode set by the user.

If the room temperature rapidly changes, the room temperature may get over the upper or lower limit when the unoccupied function is activated.

NOTE

The remote control unit should be used in the location specified in “REMOTE CONTROL UNIT INSTALLATION POSITION” on page 8.

The air conditioner’s stop order (stated in (2) / above) is valid only when the unoccupied function is operated.

OI-150-11-EG

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 11
Contents KS3082 KS3682 Mode D’EMPLOIContents FeaturesProduct Information Alert SymbolsInstallation Location Safety InstructionsUnit Display and Operation Button Names of PartsSymbols Remote Control Unit DisplayRemote Control Unit High Power button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp Mode selector button16 mm Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control unit ACL buttonFan Only Operation with the Remote Control UnitAdjusting the Fan Speed OperationCooling and DRY Mode Night Setback ModeQuiet Mode High Power ModeUnoccupied Indication Status LED Clean ModeUnoccupied Mode Cooling ModeSpecial Remarks Setting the Timer1030 pm 710 am 1100 am Present time How to set the OFF timeHow to set the on time How to set daily ON/OFF repeat timerTips for Energy Saving Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Care and Cleaning Removing and remounting the front panel How to install the air clean filterHow to clean the air clean filter Cleaning the main unit and remote control unitTrouble Possible Cause Remedy TroubleshootingWired Remote Controller Operating RangeTable DES Matières CaractéristiquesConseils DE Sécurité Symboles ’AVERTISSEMENTEmplacement D’INSTALLATION Informations SUR LE ProduitNOM DES Pièces Symboles Télécommande AffichageOn TIME/OFF Time TélécommandeCapteur Bouton de temporisateur 1 heure 1 HR. TimerSélecteur de mode Mode Bouton de haute puissance High Power32 x 5/8 4 x 16 mm Utilisation DE LA TélécommandeClimatiseur élément intérieur Récepteur Télécommande Bouton ACLVitesse manuelle du ventilateur Fonctionnement Avec TélécommandeFonctionnement Réglage de la vitesse du ventilateurEn mode de refroidissement et séchage et Mode économie nocturneMode de silencieux Quiet Mode de fonctionnement à haute puissanceIndication de pièce inoccupée Fonction Pièce Etat Mode de voyant de nettoyage LED CleanMode Pièce inoccupée Unoccupied En mode de refroidissementRéglage DU Temporisateur Remarques SpécialesPour annuler une programmation Réglage du moment de mise à l’arrêtRéglage du moment de mise en marche 1030 p.m 710 a.m 1100 a.m ’heure actuelle Marche ArrêtConseils Pour Économiser L’ÉNERGIE Emploi DU Temporisateur 1 HeureRéglage DU Flux D’AIR Entretien ET Nettoyage Fonctionnement SansDépose et remise en place du panneau avant Installation du filtre de nettoyage d’airNettoyage de l’appareil principale et de la télécommande Nettoyage du filtre de nettoyage d’airPanne Cause possible Remède Télécommande FilaireGuide DE Dépannage Plage DE Températures DE FonctionnementIshida Make up USレター 白ページ Ishida Make up USレター 白ページ Sanyo Ave., San Diego