Sensor

A temperature sensor inside the remote control unit senses the room temperature.

ON/OFF operation button

This button is for turning the air conditioner on and off.

1 HR. TIMER button (1-HOUR OFF TIMER)

: When you press this button, regardless of whether the unit is operating or stopping, the unit operates for one hour and then shuts down.

Temperature setting buttons (TEMP.)

Press the

button to increase the set temperature.

Press the

button to reduce the set temperature.

The temperature setting changes by 1 °C or 2 °F each time one of the TEMP. buttons is pressed.

MODE selector button

Use this button to select DRY, COOL or FAN mode.

(DRY)

: The air conditioner reduces the humidity in the room.

(COOL) : The air conditioner makes the room cooler.

(FAN)

: The air conditioner works only as a circulation fan.

NIGHT SETBACK button

For details, see “4. Night Setback Mode”. When you press this button in the DRY or COOL mode, the mark appears in the display, and the remote control unit will automatically adjust the set temperature to save energy.

HIGH POWER button

: If this button is pressed during DRY, COOL or FAN operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature.

The fan speed is 1step above ‘‘HIGH’’.

CLOCK button

UNOCCUPIED button

For details, see “8. UNOCCUPIED Mode”. When you press this button, the mark appears in the display. And the remote control unit will automatically prevent the room temperature from increasing too much when no one is in the room.

ACL button (ALL CLEAR)

Puts the remote control unit into pre-operation status. Always press this button after replacing the batteries.

NOTE

(Cover closed)

The illustration above pictures the remote control unit after the cover has been opened.

The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals. If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner’s position.

The indoor fan runs continuously when the system is in normal operation. It does not turn off when the desired room temperature is reached. If Night Set Back mode is selected, the fan will turn off intermittently during cooling operation in order to control air flow.

OI-150-7-EG

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 7
Contents KS3082 KS3682 Mode D’EMPLOIContents FeaturesProduct Information Alert SymbolsInstallation Location Safety InstructionsUnit Display and Operation Button Names of PartsSymbols Remote Control Unit DisplayRemote Control Unit High Power button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp Mode selector button16 mm Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control unit ACL buttonFan Only Operation with the Remote Control UnitAdjusting the Fan Speed OperationCooling and DRY Mode Night Setback ModeQuiet Mode High Power ModeUnoccupied Indication Status LED Clean ModeUnoccupied Mode Cooling ModeSpecial Remarks Setting the Timer1030 pm 710 am 1100 am Present time How to set the OFF timeHow to set the on time How to set daily ON/OFF repeat timerAdjusting the Airflow Direction Using the 1-HOUR OFF TimerTips for Energy Saving Care and Cleaning Removing and remounting the front panel How to install the air clean filterHow to clean the air clean filter Cleaning the main unit and remote control unitTrouble Possible Cause Remedy TroubleshootingWired Remote Controller Operating RangeTable DES Matières CaractéristiquesConseils DE Sécurité Symboles ’AVERTISSEMENTEmplacement D’INSTALLATION Informations SUR LE ProduitNOM DES Pièces Symboles Télécommande AffichageOn TIME/OFF Time TélécommandeCapteur Bouton de temporisateur 1 heure 1 HR. TimerSélecteur de mode Mode Bouton de haute puissance High Power32 x 5/8 4 x 16 mm Utilisation DE LA TélécommandeClimatiseur élément intérieur Récepteur Télécommande Bouton ACLVitesse manuelle du ventilateur Fonctionnement Avec TélécommandeFonctionnement Réglage de la vitesse du ventilateurEn mode de refroidissement et séchage et Mode économie nocturneMode de silencieux Quiet Mode de fonctionnement à haute puissanceIndication de pièce inoccupée Fonction Pièce Etat Mode de voyant de nettoyage LED CleanMode Pièce inoccupée Unoccupied En mode de refroidissementRéglage DU Temporisateur Remarques SpécialesPour annuler une programmation Réglage du moment de mise à l’arrêtRéglage du moment de mise en marche 1030 p.m 710 a.m 1100 a.m ’heure actuelle Marche ArrêtRéglage DU Flux D’AIR Emploi DU Temporisateur 1 HeureConseils Pour Économiser L’ÉNERGIE Entretien ET Nettoyage Fonctionnement SansDépose et remise en place du panneau avant Installation du filtre de nettoyage d’airNettoyage de l’appareil principale et de la télécommande Nettoyage du filtre de nettoyage d’airPanne Cause possible Remède Télécommande FilaireGuide DE Dépannage Plage DE Températures DE FonctionnementIshida Make up USレター 白ページ Ishida Make up USレター 白ページ Sanyo Ave., San Diego