Sanyo KS3682 Using the 1-HOUR OFF Timer, Tips for Energy Saving, Adjusting the Airflow Direction

Page 14

01_KS3682_EN.fm Page 14 Friday, February 12, 2010 12:26 PM

USING THE 1-HOUR OFF TIMER

1. 1-Hour OFF Timer

This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed.

The indicator in the display indicates that this function is operating.

Setting procedure:

Regardless of whether the unit is operating or stopped, press the 1 HR. TIMER button.

appears in the display.

Cancellation procedure:

Press the ON/OFF operation button to turn the unit off, wait for the unit to stop operating, and then press the ON/OFF operation button again.

The 1-Hour Timer function is now cancelled and the unit operates normally.

NOTE

If, while the 1-Hour Timer function is operating, the 1HR. TIMER button is pressed once to cancel the function and then again, the unit continues to operate for one hour from that point in time and then stops.

It is not possible to use the OFF Timer and 1-Hour OFF Timer together. Whichever function is set last takes precedence. If the 1 HR. TIMER button is pressed while the TIMER OFF function operates, the OFF Timer is cancelled and the unit will stop operating one hour later.

2.Operation together with the daily ON/OFF repeat timer

The 1-Hour OFF Timer setting is given priority over the DAILY ON/ OFF REPEAT setting.

TIPS FOR ENERGY SAVING

Do not

Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged.

Let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.

Do

Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.

To prevent conditioned air from escaping, keep windows, doors and any other openings closed.

14

ADJUSTING THE AIRFLOW DIRECTION

1. Horizontal

The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right.

CAUTION

When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way to the right or left, condensation may begin to form around the air vent and drip down.

2. Vertical

The vertical airflow can be adjusted by moving the flap with the remote control unit. Do not move the flap with your hands. Confirm that the remote control unit has been turned on. Use the FLAP button to set either the sweep function or one of the six airflow direction settings.

A. Sweep function

The flap starts moving up and down to deliver air over the sweep range.

B. Setting the airflow manually

 

SWEEP

Referring to the above

COOL

 

illustration, use the

DRY

SWEEP

FLAP button to set the

 

 

airflow direction within

 

FAN

the range used during

 

 

 

cooling or

 

 

dehumidifying

 

 

operation.

 

 

C. Auto flap function

The flap is set to the recommended position.

NOTE

• The flap automatically closes when the unit is off.

OI-150-14-EG

Image 14
Contents Mode D’EMPLOI KS3082 KS3682Features ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Mode selector button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp High Power buttonACL button Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control unit 16 mmOperation Operation with the Remote Control UnitAdjusting the Fan Speed Fan OnlyHigh Power Mode Night Setback ModeQuiet Mode Cooling and DRY ModeCooling Mode LED Clean ModeUnoccupied Mode Unoccupied Indication StatusSetting the Timer Special RemarksHow to set daily ON/OFF repeat timer How to set the OFF timeHow to set the on time 1030 pm 710 am 1100 am Present timeTips for Energy Saving Using the 1-HOUR OFF TimerAdjusting the Airflow Direction Care and Cleaning Cleaning the main unit and remote control unit How to install the air clean filterHow to clean the air clean filter Removing and remounting the front panelOperating Range TroubleshootingWired Remote Controller Trouble Possible Cause RemedyCaractéristiques Table DES MatièresInformations SUR LE Produit Symboles ’AVERTISSEMENTEmplacement D’INSTALLATION Conseils DE SécuritéNOM DES Pièces Télécommande Affichage SymbolesTélécommande On TIME/OFF TimeBouton de haute puissance High Power Bouton de temporisateur 1 heure 1 HR. TimerSélecteur de mode Mode CapteurBouton ACL Utilisation DE LA TélécommandeClimatiseur élément intérieur Récepteur Télécommande 32 x 5/8 4 x 16 mmRéglage de la vitesse du ventilateur Fonctionnement Avec TélécommandeFonctionnement Vitesse manuelle du ventilateurMode de fonctionnement à haute puissance Mode économie nocturneMode de silencieux Quiet En mode de refroidissement et séchage etEn mode de refroidissement Mode de voyant de nettoyage LED CleanMode Pièce inoccupée Unoccupied Indication de pièce inoccupée Fonction Pièce EtatRemarques Spéciales Réglage DU Temporisateur1030 p.m 710 a.m 1100 a.m ’heure actuelle Marche Arrêt Réglage du moment de mise à l’arrêtRéglage du moment de mise en marche Pour annuler une programmationConseils Pour Économiser L’ÉNERGIE Emploi DU Temporisateur 1 HeureRéglage DU Flux D’AIR Fonctionnement Sans Entretien ET NettoyageNettoyage du filtre de nettoyage d’air Installation du filtre de nettoyage d’airNettoyage de l’appareil principale et de la télécommande Dépose et remise en place du panneau avantPlage DE Températures DE Fonctionnement Télécommande FilaireGuide DE Dépannage Panne Cause possible RemèdeIshida Make up USレター 白ページ Ishida Make up USレター 白ページ Sanyo Ave., San Diego