WTI CMS-16; Console Management Switch -- User's Guide

No Serviceable Parts Inside; Authorized Service Personnel Only

Do not attempt to repair or service this device yourself. Internal components must be serviced by authorized personnel only.

Shock Hazard - Do Not Enter

Choc Hasard - N'entrent

Schocke Hazard - Test Nicht Betrete

Otro Hazard - Do Non Entrano

Nameplate Power Warning

This device should only be operated with the type of power source indicated on the instrument nameplate. If you are not sure of the type of power service available, consult your local power company.

Connect unit only to a properly measured supply. Use only three wire cord which is provided with the unit.

Abouchent unité qu'aux convenable mesura approvisionnement. Usage qu'à trois fil corde laquel est approvisionna avec la unité.

Anschliesse einheit nur bis ein angebracht gemessen nachschub. Gebrauch nur drei draht schnur welche ist verschaffen mit das einheit.

Connect unità solo a un proper misurata fornirle. Adoperano solo tre wire spago quale è fornii con gli unità.

Battery Replacement

This device may include a lithium battery powered circuit. If the battery is incorrectly replaced or mistreated, there is a danger of explosion and a risk of personal injury. Do not attempt to recharge the battery, disassemble it, immerse it in water, or dispose of it in a fire. Battery replacement may only be performed by authorized service personnel.

Rack Mount Installation

When installing this device in an instrument rack, the following factors must be accounted for:

1.Enclosed Racks: Enclosed racks must provide adequate ventilation. Make certain that the rack is not overly crowded and note that each unit in the rack generates its own heat. An enclosed rack should have louvered sides and a fan to circulate cooling air. The maximum temperature for the equipment in this environment is 45° C.

When mounting the unit in an enclosed rack with a ventilation fan at the top of the rack, note that excessive heat generated by devices at the bottom of the rack can be drawn upward and into the ventilation slots of units located at the top. Make certain to provide adequate ventilation for equipment installed at the bottom of the rack.

file:///C/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (2 of 59) [11/15/2000 10:52:02 AM]

Image 2
Contents CMS-16 Rack Mount Installation Nameplate Power WarningBattery Replacement Table of Contents WTI CMS-16 Console Management Switch -- Users Guide Appendices List of FiguresIntroduction Typographic ConventionsBold Font Unit DescriptionFront Panel Back Panel Power Cable Receptacle Power SwitchGetting Started Using Other Parameters for this Overview Optional Apply Power to the CMSSystem SetUp Ports Communication ParametersConnecting your PC to the CMS Communicating with the CMS UnitDisplay Free Any Undefined Enter /H for Command Menu AC Powered Units Hardware InstallationConnecting Power to the CMS Unit DC Powered UnitsConfigure Option Switches Default Baud Rate Sw1, Sw2, Sw3Default Command Echo Sw7 Default Handshake Sw4, Sw5Default Response Message Format Sw6 Application Example Initialize Unit to Default SettingsConnecting Devices to the CMS CMS Application Example Not to Scale Configuration Access to the CMS Command ModePassword Functions $ telnet 192.1.1.1 EnterSupervisor Password Port PasswordsDefining the Site ID and Supervisor Password Port Configuration Configuration Conventions3. RS232 Port Configuration Menus Port ModesStop Bits Default = CTS/RTSAT&C1$D2S0=1 WTI CMS-16 Console Management Switch -- Users Guide Network Port Configuration Menu Telnet Port ParametersNetwork Parameters Menu Supervisor Mode Only Implementing IP Security Security menu Figure Copying Parameters to All Ports Copy Port Parameters Menu Port Status Screen /S Status ScreensSave User Selected Parameters Port Diagnostics Screen /SD Port Status Screen Supervisor Mode, Defaults ShownPort Name Status Baud COM HS Mode BUF CTS Network Status Screen /SN Port Parameters Screens /WWP xx Enter Port Connection and Disconnection Any-to-Any ModeOperation Disconnecting Ports Enter Defining Hunt Groups Hunt Group ExamplePassive Mode Buffer ModePort Buffers Reading Data from Buffer Mode PortsXx Enter Saving and Restoring Configuration Parameters Modem ModeSending Parameters to a File Restoring Saved ParametersUpgrading CMS Firmware Command Reference Guide Command ConventionsCommand Response Terse VerboseCommand Summary Command Availability Supervisor UserCommand Set Enter Enter Command ModeEnter+++Enter Resident Disconnect Sequence ConnectErase Buffer CP Copy RS232 Port ParametersThird Party Disconnect Help Default and TestSet System Parameters Set RS232 Port Parameters Display Site IDSet Network Port Parameters Display Port Status SD Display Port DiagnosticsReset Network Port SN Display Network StatusDisplay Port Parameters Who UF Upgrade FirmwareSave Parameters Format /X Enter Exit Command ModeAppendix A. RS232 Port Interface Power Appendix B. SpecificationsAppendix C. Customer Service Stop Bits 1 orTrademark and Copyright Information Trademarks Used in this Manual