Western Telematic CMS-16 manual Defining the Site ID and Supervisor Password

Page 21

WTI CMS-16; Console Management Switch -- User's Guide

The Port Passwords (or User Passwords) allow system administrators to restrict access to a specific group of ports. When the CMS command mode is accessed with a Port Password, users may only connect to the RS232 Ports to which they have been granted access, and review configuration parameters for those ports. Port Passwords do not grant access to CMS configuration commands.

The configuration menus (/P) for each RS232 port allow a Port Password to be assigned to each individual port. In order to allow a Port Password to grant access to a series of CMS ports, the same Port Password is assigned to each port in the series.

For example, if the Port Password "test" is assigned to ports 3, 4, and 5, then when "test" is entered at the Password Prompt, the user will only be able to connect to ports 3, 4, and 5, and will only be able to view parameters for ports 3, 4, and 5.

If desired, all CMS ports can function as both a Supervisor Port and a User Port, depending on which password is entered at the login prompt. However, if you wish to prevent a port from being able to access the Supervisor Mode at all (even with the Supervisor Password), the Supervisor Mode can be disabled at the RS232 Ports and the Network Port using the Port Configuration menus as described in Section 5.5. Note however, that the Supervisor Mode cannot be disabled at Ports 1 and 2; these ports are designated as SetUp Ports, and are always allowed password protected access to Supervisor Level commands.

5.4. Defining the Site ID and Supervisor Password

Before configuring individual ports, the Site ID and Supervisor Password should be defined. The Site ID can be used to indicate the location or name of the CMS unit, and the Supervisor Password is used to restrict access to sensitive command functions. Both the Site ID message and Supervisor Password are defined via the System Parameters menu (/F).

Note:

The Site ID cannot include double quotes.

The Supervisor Password cannot include an asterisk, forward slash, spaces, or double quotes.

Both the Site ID and Supervisor Password will be cleared if the CMS is initialized to default settings.

The System Parameters Menu is only available in Supervisor Mode.

1.Access the Command Mode. When the "CMS>" prompt appears, type /F [Enter] to display the System Parameters Menu.

2.Site ID Message: (Up to 32 characters; Default = undefined) Type 1 and press [Enter], the Site I.D. Prompt will appear. Key in the desired text and press [Enter] . To display the Site I.D., type /J [Enter]. The Site ID is also listed on the Port Status and Port Diagnostic Screens.

3.Supervisor Password: (Up to 32 characters; Default = undefined) Type 2 and press

file:///C/WEBPAGE/guides/cms/html/rev_b/Cmsguide.htm (21 of 59) [11/15/2000 10:52:02 AM]

Image 21
Contents CMS-16 Nameplate Power Warning Battery ReplacementRack Mount Installation Table of Contents WTI CMS-16 Console Management Switch -- Users Guide List of Figures AppendicesTypographic Conventions IntroductionUnit Description Front PanelBold Font Power Cable Receptacle Power Switch Getting StartedBack Panel System SetUp Ports Apply Power to the CMSUsing Other Parameters for this Overview Optional Communication ParametersCommunicating with the CMS Unit Connecting your PC to the CMSDisplay Free Any Undefined Enter /H for Command Menu Connecting Power to the CMS Unit Hardware InstallationAC Powered Units DC Powered UnitsDefault Baud Rate Sw1, Sw2, Sw3 Configure Option SwitchesDefault Handshake Sw4, Sw5 Default Response Message Format Sw6Default Command Echo Sw7 Initialize Unit to Default Settings Connecting Devices to the CMSApplication Example CMS Application Example Not to Scale Access to the CMS Command Mode Configuration$ telnet 192.1.1.1 Enter Password FunctionsPort Passwords Supervisor PasswordDefining the Site ID and Supervisor Password Configuration Conventions Port ConfigurationPort Modes 3. RS232 Port Configuration MenusCTS/RTS Stop Bits Default =AT&C1$D2S0=1 WTI CMS-16 Console Management Switch -- Users Guide Telnet Port Parameters Network Port Configuration MenuNetwork Parameters Menu Supervisor Mode Only Implementing IP Security Security menu Figure Copying Parameters to All Ports Copy Port Parameters Menu Status Screens Save User Selected ParametersPort Status Screen /S Port Status Screen Supervisor Mode, Defaults Shown Port Diagnostics Screen /SDPort Name Status Baud COM HS Mode BUF CTS Port Parameters Screens /W Network Status Screen /SNWP xx Enter Any-to-Any Mode OperationPort Connection and Disconnection Disconnecting Ports Enter Hunt Group Example Defining Hunt GroupsBuffer Mode Passive ModeReading Data from Buffer Mode Ports Xx EnterPort Buffers Modem Mode Saving and Restoring Configuration ParametersRestoring Saved Parameters Sending Parameters to a FileUpgrading CMS Firmware Command Conventions Command Reference GuideTerse Verbose Command ResponseCommand Availability Supervisor User Command SummaryEnter Enter Command Mode Command SetConnect Enter+++Enter Resident Disconnect SequenceCP Copy RS232 Port Parameters Third Party DisconnectErase Buffer Default and Test Set System ParametersHelp Display Site ID Set Network Port ParametersSet RS232 Port Parameters Reset Network Port SD Display Port DiagnosticsDisplay Port Status SN Display Network StatusUF Upgrade Firmware Save ParametersDisplay Port Parameters Who Exit Command Mode Appendix A. RS232 Port InterfaceFormat /X Enter Appendix C. Customer Service Appendix B. SpecificationsPower Stop Bits 1 orTrademarks Used in this Manual Trademark and Copyright Information