tthe keypad will start beeping to indicate that learn mode has been activated.
2.Press the ARM button on the remote control
tit will send a transmission signal. The panel will confirm if a user is found with the message “Found”.
3.Press to confirm.
4.Repeat the actions 1 - 3 to follow up for all
5 buttons (use the navigation button to switch to the next user number).
For remote control 2 take user numbers 26 - 30 etc.
Telephone connection
To transmit events, the system needs to be connected to a telephone line. Follow steps 8 - 9 to program the telephone numbers.
If no telephone line is connected, the dialer must be turned off:
1.Press 175 1 t the display shows: “Dialer A Option
2.Press 1 t the display shows:
3.To check: press Ctrl simultaneously
tthe display changes to clear text mode and shows “Enable Dialer No”.
4.Press to go back and continue with step 10 “Testing Installation”.
Telephone numbers
The telephone numbers (max. 8) which are dialed in case of an event can be up to
16 digits long. Default setting: Telephone number 8 is the call back number of the Control Monitoring Station (CMS).
1.Telephone number 1:
press 181 1 “tel.number”
2.Choose a reporting format for this number. a) Number related to a phone:
press 182 1 2
tan alarm signal will be sent out to this number when an event occurs.
b)Call goes out to a CMS station:
CID format: press 182 1 1
SIA format: press 182 1 10
3.Repeat actions 1 - 2 to follow up for telephone numbers 2 - 8 (use the naviga-
tion button to switch to the next tele- phone number).
There are 11 different reporting formats that can be selected for each telephone number. The formats are listed in the Installer Manual.
Identification code
When connected to a monitoring station you can program an individually identification code:
Area A: press 62 1 ”code” (4 digit code
Testing Installation
To test the strength of the signal received on
the panel: press 200 14
Any time a signal is detected, the keypad beeps and displays the received signal strength in % for 30 sec.
To test all detectors on their function and transmission range, change to walk test mode.
In the walk test mode the panel will not send out any alarms and the working range will be less than in the normal op- erating mode - EN50131 requirement.
1.Start walk test: press 200 6 t the keypad will start beeping to indicate
that walk test mode has been activated.
2.Activate the installed detectors with a
magnet
tit will send a transmission signal (for more details see Installation Instruction of the detector). The panel will give a notification signal each time a detector signal is re- ceived and will show the detector number on the display.
3.To end this mode: press .
tthis will take you back to the normal mode.
4. To check out all received signals in event log: press.
5.To clear events in the log: press or enter the installer code (see User Manual 3.15.3).
The programming is finished now and the system ready to operate.
Don’t forget to reconnect the internal siren!