Preparation - General information | EN |
–Before connecting the battery or switching the main power supply on, unplug the in- ternal siren for the time of the installation (small plug with cable, directly on the left lower side of the display).
–If the internal buzzer starts beeping: Press to silence it.
–To exit the system at any time: Press and hold the button .
Reset back to factory setting:
–Reset all pins and numbers: Press 200 9 .
–Reset all individually changed parameters: Press 200 10 .
Language setting
1.Press Ctrl simultaneously t the “Local Mode” opens.
2.Scroll with the buttons / to the posi- tion “Language” and press to select.
3.Scroll with the buttons / to the lan- guage you prefer and press to save.
4.To exit press and hold the button .
tthe keypad will start beeping to indicate that learn mode has been activated.
2.Press the tamper contact on the detector or remove the magnet from the door contact
tit will send a transmission signal. The panel will confirm if a detector is found with the message “Found”.
3.Press to confirm.
4.Repeat actions 1 - 3 to follow up for the
Start programming
Programming the system (steps 2
1.Press user code “147258”
tthe displays shows: “CLIENT:USER”.
2.Press installer code “258369”
tthe displays shows: “ISTALLER:USERS”.
Clock setting
1. Set time: press 26 1 ”HHMM”
2.Set weekday: press 26 2 ”DAY” (Sunday = 1, Monday = 2…etc.)
3.Set date: press 26 3 ”DDMMYY”
4.Activate automatic daylight saving (default Europe GMT+1): press 26 4 1
Detectors
Learn the wireless detectors (max.16), be- fore installing, to the panel. Default settings:
-Zones 1 and 2 are delayed for entry route.
-Zones 3 - 8 are set for normal zones.
-Zones 9 - 16 are set for Stay zones.
We recommend using:
-Zone 1: magnet contact from the entry door.
-Zone 2: first motion detector for the surveil- lance of the entry area (control panel).
1.For zone 1: press 164 1
zones 2 - 16 (use the navigation button to switch to the next zone).
If a detector could not be learned it is either already learned to the panel, or the transmis- sion signal was not received - try again. Already learned detectors can be checked in
“Find Detector” mode: press 166
Entry delay time
The entry delay time is set by default to 20 sec. To change the time
1.Zone 1: press 144 1 ”seconds”
2.Zone 2: press 144 2 ”seconds”
Exit delay time
The exit delay time is set by default to 30 sec. To change the time (0 - 255 seconds) per area:
Area A: press 60 1 ”seconds”
Remote control
Learn a remote control (max. 16) to the system starting with user number 21 - 25. Default setting:
User 21: | ARM | User 22: | DISARM | x |
User 23: | STAY | User 24: |
|
|
|
|
|
| |
User 25: | FREE | (simultaneously ) PANIC/SOS |
|
1.Remote control 1: press 18 21