Thermo Products MHA1-125N, MDA1-50N, MHA1-75N MDA1/MHA1-50S00S4426, Description Part Number QTY

Page 52

All installations and services must be performed by qualified service personnel.

APPENDIX D: PARTS PACKAGE COMPONENTS

INSTALLATION PARTS PACKAGE

MDA1/MHA1-50(S00S4426)

DESCRIPTION

PART NUMBER

QTY.

WIRE NUT

300132

2

#8X1/2 TEK SCREWS

300208

2

for mounting 2X4 J-box

 

 

#10-32X1/2 GND SCREW

300109

1

#10-32 HEX NUT

300110

1

3/16” DIA. STAR WASHER

300270

1

2X4 J- BOX

350024

1

2X4 J- BOX COVER

350020

1

GROUNDING INSTRUCTIONS

MG-966

1

HEYCO SR 34-2

350016

1

HEYCO UB-875

350750

1

INSTALLATION PARTS PACKAGE

MHA1/MDA1-75(S00S4427)/MDA1/MHA1-100 (S00S4428) / MDA1/MHA1-125

(S00S4429)

DESCRIPTION

PART NUMBER

QTY.

WIRE NUT

300132

2

#8X1/2 TEK SCREWS

300208

2

for mounting 2X4 J-box

 

 

#10-32X1/2 GND SCREW

300109

1

#10-32 HEX NUT

300110

1

3/16” DIA. STAR WASHER

300270

1

2X4 J- BOX

350024

1

2X4 J- BOX COVER

350020

1

GROUNDING INSTRUCTIONS

MG-966

1

HEYCO SR 34-2

350016

1

HEYCO UB-875

350750

1

3” X 4” TAPERED TRANSITION

14310

1

49

Image 52
Contents Induced Draft Highboy COUNTERFLOW/HORIZONTAL GAS Furnace Section Safety II. Installation Guidelines Page Packaging Shipping DamageSafety II. Installation Guidelines CodesInstallation Location Closet and Alcove InstallationStandard Clearances Refer to FigureNon-combustible Material Plenum Flue or Vent All Models Covered by This ManualAir for Combustion and Ventilation MDA1 Horizontal Installation MDA1 Installed Horizontal Filters/ Filter Installation Duct Work and Air ConditioningUse of Non-Thermo Pride Filter Retention Means Optional Thermo Pride Filter RackFPM FormulaVenting Replacing An Existing Furnace From a Common Vent Carbon Monoxide Poisoning HazardCondensing in the Chimney Page Page Vent Connection to Inducer Inducer Mounting Sidewall Venting Automated Literature FAXHorizontal Size and Lengths for Horizontal Vents Horizontal Size and Length for Sidewall VentingGAS Piping General GAS Piping Fire or Explosion HazardPage Installation of Natural GAS Piping Typical Gas PipingInstallation of Propane GAS Piping Steel Pipe Size for Natural Gas IPSPage Field Wiring and Replacing Wiring ElectricalElectronic Air Cleaner and Humidifier Connections Room ThermostatBlower and Control Panel To delay fan Set Switch Initial StartupWhat to do if YOU Smell GAS To Turn Off Gas To Appliance Adjustment Of Heat Input Rate Page Burner Adjustment Setting Supply Air Temperature Rise Typical Observation of Main Burner FlamesCheckout Procedure Important Remove flue blockage when doneDiagnostic Features LED will also flash once at power-upShut off gas and disconnect power before continuing General InspectionHouse Air Blower Filter Replacement Filter Maintenance ProcedureReturn Air Filter VI. Installers Instructions to User Appendix a Sources for Reference Standards Appendix B Sequence of Operations Sequence of Operations for Heating SystemMode of Operation Control System Action Appendix C Troubleshooting Flowcharts Heating SystemYes Is ignitor positioned Correctly? Does system run until thermostat is satisfied? MDA1/MHA1-50S00S4426 Description Part Number QTYAppendix E Replacement Parts List MHA1 Page Replacement Parts List MDA1 Page Appendix F Wiring Diagram Page Appendix G MID-EFFICENCY Furnace Specifications MID-EFFICIENCY Highboy GAS Furnace SPECIFICATIONS5Nominal temp. rise Heating fan speed