Thermo Products MHA1-125N, MDA1-50N, MHA1-75N, MHA1-100N Nominal temp. rise Heating fan speed

Page 60

All installations and services must be performed by qualified service personnel.

MID-EFFICIENCY COUNTERFLOW / HORIZONTAL GAS FURNACE SPECIFICATIONS5

Model NO.

MDA1-50

 

MDA1-75

 

MDA1-100

MDA1-125

Heat input rate (BTUH)

50,000

 

75,000

 

 

100,000

 

125,000

Heating capacity (BTUH)1

40,000

 

60,000

 

 

81,000

 

101,000

Nominal temp. rise

 

 

 

 

 

70°

F.

 

 

 

 

 

Heating fan speed

 

LOW

 

MD LOW

 

LOW

 

 

MD LOW

Burner orifice size for nat. gas

 

 

 

 

 

 

0.0935”

(#42)

 

 

 

 

 

 

Burner orifice size for L.P. gas

 

 

 

 

 

 

0.0591” (1.5 mm)

 

 

 

 

 

AFUE %

 

81.0

 

 

80.0

 

 

81.0

 

 

81.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height of casing

 

 

 

 

 

 

44-1/4”

 

 

 

 

 

Width of casing

 

17”

 

 

17”

 

17”

 

 

17”

 

Depth of casing

 

 

 

 

 

27

½”

 

 

 

 

 

Warm air outlet2

15” x 18”

 

15” x 18”

 

19” x 18”

22” x 18”

Return air inlet2

15” x 18”

 

15” x 18”

 

19” x 18”

22” x 18”

Approx. shipping weight

131 LBS

 

143 LBS

 

170 LBS

186 LBS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dia. of flue (vertical vent)

 

3”

 

 

4”

 

4”

 

 

4”

 

Dia. of flue (sidewall vent)3

 

3”

 

 

4”

 

4”

 

 

4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM @ .2” & .5” W.C. external

.2”

 

.5”

 

.2”

 

.5”

 

.2”

.5”

.2’

.5”

static pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@HI speed

900

 

730

 

1400

 

1220

 

 

1595

 

1370

 

2075

 

1790

@MH speed

835

 

680

 

1200

 

1075

 

 

1460

 

1260

 

1830

 

1605

@ML speed

-

-

 

926

850

 

 

1360

 

1170

 

1620

 

1430

@LO speed

580

425

 

765

700

 

 

1220

 

1075

 

1345

 

1265

 

 

 

 

 

 

 

 

Blower motor type & frame

 

 

 

Permanent split capacitor, air over, 48 Y

 

 

 

Blower motor nominal HP

 

1/5

 

 

1/3

 

 

1/2

 

 

3/4

 

Blower motor full load amps

 

3.25

 

 

6.0

 

 

8.0

 

 

11.0

 

Motor shaft diameter

 

 

 

 

 

 

½”

 

 

 

 

 

 

 

Direction of rotation (shaft end)

 

 

 

 

 

 

Clockwise

 

 

 

 

 

No. of speeds

 

3

 

 

4

 

 

4

 

 

4

 

Run capacitor

10 mfd

 

10 mfd

 

10 mfd

15 mfd

 

370 VAC

 

370 VAC

 

370 VAC

440 VAC

Blower size

10-9 R DD

 

10-9 R DD

 

10-10 R DD

10-10 R DD

Size of filters

(2) –1” x 17 ¾” x

 

(2) –1” x 17 ¾” x

 

(2) – 1” x 17 ¾” x

(2) – 1” x 17 ¾”

 

 

11 ¾”

 

11 ¾”

 

13 ¾”

x 17 ¾”

Largest recommended air

 

2 Ton

 

3 Ton

 

3.5 Ton

4 Ton

conditioner4

 

 

 

 

 

 

 

 

 

 

 

 

Electrical power requirements

 

 

 

 

115 volts, 60 Hz., 1 phase

 

 

 

Min. Fuse size

15 AMP

 

15 AMP

 

15 AMP

20 AMP

 

 

 

ACCESSORY ITEMS

 

 

 

 

 

 

 

Combustible Floor Base

50DA-BASE

 

50DA-BASE

 

100CA-BASE

125CA-BASE

Horizontal Plenum Angles

 

 

 

 

 

 

AOPS4942

 

 

 

 

 

Vent Kit (top vent option)

 

 

 

 

 

 

AOPS4941

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.BTU output based on annual fuel utilization efficiency rated by manufacturer.

2.On all outlet and inlet dimensions, the first dimension is width.

3.The MHA1/MDA1 furnaces are approved for sidewall venting using only an approved sidewall power venter. Refer to Side Wall Venting section of the Installation and service manual provided with the furnace for additional information.

4.To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.

5.All specifications are subject to change without notice.

57

Image 60
Contents Induced Draft Highboy COUNTERFLOW/HORIZONTAL GAS Furnace Section Safety II. Installation Guidelines Page Packaging Shipping DamageSafety II. Installation Guidelines CodesInstallation Location Closet and Alcove InstallationStandard Clearances Refer to FigureNon-combustible Material Plenum Flue or Vent All Models Covered by This ManualAir for Combustion and Ventilation MDA1 Horizontal Installation MDA1 Installed Horizontal Filters/ Filter Installation Duct Work and Air ConditioningUse of Non-Thermo Pride Filter Retention Means Optional Thermo Pride Filter RackFPM FormulaVenting Replacing An Existing Furnace From a Common Vent Carbon Monoxide Poisoning HazardCondensing in the Chimney Page Page Vent Connection to Inducer Inducer Mounting Sidewall Venting Automated Literature FAXHorizontal Size and Lengths for Horizontal Vents Horizontal Size and Length for Sidewall VentingGAS Piping General GAS Piping Fire or Explosion HazardPage Installation of Natural GAS Piping Typical Gas PipingInstallation of Propane GAS Piping Steel Pipe Size for Natural Gas IPSPage Field Wiring and Replacing Wiring ElectricalElectronic Air Cleaner and Humidifier Connections Room ThermostatBlower and Control Panel To delay fan Set Switch Initial StartupWhat to do if YOU Smell GAS To Turn Off Gas To Appliance Adjustment Of Heat Input Rate Page Burner Adjustment Setting Supply Air Temperature Rise Typical Observation of Main Burner FlamesCheckout Procedure Important Remove flue blockage when doneDiagnostic Features LED will also flash once at power-upShut off gas and disconnect power before continuing General InspectionHouse Air Blower Filter Maintenance Procedure Filter ReplacementReturn Air Filter VI. Installers Instructions to User Appendix a Sources for Reference Standards Appendix B Sequence of Operations Sequence of Operations for Heating SystemMode of Operation Control System Action Appendix C Troubleshooting Flowcharts Heating SystemYes Is ignitor positioned Correctly? Does system run until thermostat is satisfied? MDA1/MHA1-50S00S4426 Description Part Number QTYAppendix E Replacement Parts List MHA1 Page Replacement Parts List MDA1 Page Appendix F Wiring Diagram Page Appendix G MID-EFFICENCY Furnace Specifications MID-EFFICIENCY Highboy GAS Furnace SPECIFICATIONS5Nominal temp. rise Heating fan speed