HP 3886, IM059R02, 3885 manual Engineering Data, Voltage, Amps, 1725, 3450

Page 7

Engineering Data

Maximum Diameter Solids

 

 

3885

34 in

19 mm

3886 and 3887

2 in

50 mm

Minimum Casing Thickness

516 in

8 mm

Casing Corrosion Allowance

18 in

3 mm

Minimum Working Pressure

55 psi

380 kPa

ELECTRICAL DATA 3885

Minimum Pump Submergence – Below Top of Motor Dome

6 in

152 mm

Minimum Number of Evenly Distributed Starts per Hour

 

6

Maximum Operating Temperature

40° C

104° F

Continuous Operation

Intermittent Operation

60° C

140° F

Motor Cover Oil Capacity

4.5 qts.

4.3 L

HP

RPM

Voltage

Phase

Amps

KVA

Winding Resistance

Power

Fuse/Circuit

/Hz

Code

Line to Line (Ohms)

Cable AWG

Breaker Amps

 

 

 

 

13

1725

115

1/60

9.4

M

1.92

16/3

15

13

1725

230

1/60

4.7

N

7.58

16/3

10

12

3450

115

1/60

14.5

M

1.00

16/3

20

12

3450

230

1/60

7.3

M

4.03

16/3

10

12

3450

200

3/60

3.9

R

3.8

14/4

10

12

3450

230/460

3/60

3.4/1.7

R

5.81/23.24

14/4

10/10

34

3450

230

1/60

10.0

J

2.99

14/3

15

34

3450

200

3/60

6.2

L

5.7

14/4

10

34

3450

230/460

3/60

5.4/2.7

L

4.04/16.15

14/4

10/10

1

3450

230

1/60

12.5

J

2.09

14/3

20

1

3450

200

3/60

8.1

M

2.6

14/4

10

1

3450

230/460

3/60

7.0/3.5

L

4.04/16.15

14/4

10/10

112

3450

230

1/60

15.0

H

1.16

14/3

20

112

3450

200

3/60

10.6

K

1.9

14/4

15

112

3450

230/460

3/60

9.2/4.6

K

2.87/11.46

14/4

15/10

2

3450

230

1/60

18.0

F

M-1.1/S-2.2

14/3

20

2

3450

200-230/460

3/60

12.0-11.6/5.8

K

1.66/6.62

14/4

15/10

ELECTRICAL DATA 3886 AND 3887BF

 

 

 

 

 

 

13

1725

115

1/60

9.8

M

1.92

16/3

15

13

1725

230

1/60

4.9

N

7.58

16/3

10

12

1725

115

1/60

14.5

N

1.6

16/3

20

12

1725

230

1/60

7.3

K

6.4

16/3

10

12

1725

200

3/60

3.8

K

6.55

14/4

10

12

1725

230/460

3/60

3.3/1.7

K

9.9/39.4

14/4

10/10

34

1725

230

1/60

9.4

J

5.9

14/3

15

34

1725

200

3/60

4.1

H

4.3

14/4

10

34

1725

230/460

3/60

3.6/1.8

J

5.6/22.4

14/4

10/10

1

1725

230

1/60

12.3

H

2.6

14/3

20

1

1725

200

3/60

6.0

H

4.3

14/4

10

1

1725

230/460

3/60

5.8/2.9

J

5.6/22.4

14/4

10/10

ELECTRICAL DATA 3887BHF

 

 

 

 

 

 

 

13

1725

115

1/60

12.4

M

1.00

16/3

15

13

1725

230

1/60

6.2

M

4.03

16/3

10

12

3450

115

1/60

14.5

M

1.00

16/3

20

12

3450

230

1/60

7.6

M

4.03

16/3

10

12

3450

200

3/60

4.1

R

3.8

14/4

10

12

3450

230/460

3/60

3.6/1.8

R

5.81/23.24

14/4

10/10

34

3450

230

1/60

9.4

J

2.99

14/3

15

34

3450

200

3/60

6.2

L

5.7

14/4

10

34

3450

230/460

3/60

5.4/2.7

L

4.04/16.15

14/4

10/10

1

3450

230

1/60

14.5

J

2.1

14/3

20

1

3450

200

3/60

8.6

M

2.6

14/4

10

1

3450

230/460

3/60

7.5/3.8

L

4.0/16.2

14/4

10/10

112

3450

230

1/60

18.0

F

M-1.1/S-2.2

14/3

20

112

3450

200-230/460

3/60

10.0-9.6/4.8

K

1.66/6.62

14/4

15/10

2

3450

230

1/60

18.0

F

M-1.1/S-2.2

14/3

20

2

3450

200-230/460

3/60

12.0-11.6/5.8

K

1.66/6.62

14/4

15/10

7

Image 7
Contents Owner’s Information Table of ContentsSliderail System Lifting of PumpPiping Pump Motor Control Panels Access DoorsWiring and Grounding Liquid Level ControlsOperation MaintenancePeriodic Maintenance Frequency Required MaintenanceClockwise Disassembly/AssemblyMechanical Seal Replacement Power Cable ReplacementMotor Replacement Start Capacitor Replacement1725 Engineering DataVoltage Amps357 Repair Parts Diagram for Models 3885, 3886458 376 338 372D 340 101 351 100 484B 457 436 341 112A 412M 371H 387371C 195C 351AModel 3885 Repair Parts Table Part Name Model 3886 and 3887 Repair Parts TableOptional Lengths Typical Plumbing and Installation Typical 2 Slide Rail InstallationSymptom Probable Cause Recommended Action Trouble ShootingÍndice Información del propietarioTópico Sistema de riel corredizo Levantamiento de la bombaTuberías Alambrado y conexión a tierra Puertas de accesoControles del nivel de líquido Paneles de control del motor de la bombaBloquear LA Corriente OperaciónMantenimiento ADVERTENCIA. Esto Puede Producir Graves Lesiones PersonalesReemplazo DEL Sello Mecánico Mantenimiento periódicoDesmontaje/Reensamblaje Frecuencia Mantenimiento RequeridoReemplazo DEL Motor Reemplazo DEL Condensador DE ArranqueDatos Eléctricos 38867BHF Datos de ingenieríaDatos Eléctricos Datos Eléctricos 3886 Y484B 457 436 341 112A 412M Diagrama de repuestos para los Modelos 3885, 3886 y371H 387371C 195C 351A Tabla de repuestos para el Modelo 1725 RPM 3450 RPM Máx ⁄3 HP Tabla de repuestos para los Modelos 3886 y11⁄2 HP Lbs Plomería e instalación típicas Instalación típica del riel corredizo de 2 pulgSíntoma Causa Probable Acción Recomendada Identificación y resolución de problemasTable des matières Informations pour le propriétaireSujet Système à rail de guidage glissière Levage de la pompeTuyauterie Câblage et mise à la terre Tableaux de commande des moteurs de pompeTrappes de visite Régulateurs de niveauEntretien UtilisationEntretien périodique ET Mise À LA Terre » ET « Utilisation » DU Manuel « Remplacement DE LA GarnitureDémontage et remontage FréquenceRemplacement DU Moteur Remplacement DU Condensateur DE DémarrageTension Données techniquesIntensité a Dessin en coupe modèles 3885, 3886 et Pièces de rechange et matériaux modèle ⁄3 hp ⁄2 hp ⁄4 hp 11⁄2 hp Pièces de rechange et matériaux modèles 3886 et’art 725 tr/min 450 tr/minSystème à rail de guidage type de 2 po Installations typesAnomalies Causes Probables Correctifs Recommandés Diagnostic des anomalies