HP 3885 Disassembly/Assembly, Mechanical Seal Replacement, Power Cable Replacement, Clockwise

Page 5

Disassembly/Assembly

WARNING

FAILURE TO DISCONNECT AND

LOCKOUT ELECTRICAL POWER

Hazardous

BEFORE ATTEMPTING ANY

voltage

MAINTENANCE CAN CAUSE

 

SHOCK, BURNS OR DEATH.

NOTICE: FOLLOW ALL SAFETY AND LIFTING INSTRUCTIONS PROVIDED IN THIS MANUAL.

Following the slide rail instructions, remove the pumping unit from the sewage containment area.

WARNING

UNIT MUST BE FLUSHED AND

DISINFECTED, INSIDE AND OUT,

 

 

PRIOR TO SERVICING.

Biohazard can cause serious personal injury.

MECHANICAL SEAL REPLACEMENT

1. Follow ALL instructions provided in the “DISASSEMBLY ” section of this manual.

2. To gain access to the pump impeller and mechanical seal remove the four casing hex cap screws (372D). Remove casing (100) and casing gasket (351); discard the gasket.

5. Remove and discard the mechanical seal and stationary seat assembly. DO NOT damage the motor shaft or the stationary seat bore.

6. Inspect and wipe clean the stationary seat bore.

7. To install the new stationary seat into the seal housing, lubricate the stationary seat bore and motor shaft with clean motor insulating oil. Using Goulds mechanical seal installation tool (A02A013), slide the stationary seat fully and squarely into the seal housing.

8. With a clean, lint free cloth, wipe the stationary face clean of all lubricating oil or debris. DO NOT scratch or otherwise damage the seal face.

9. Lubricate the inside of the rotary elastomer with clean motor insulating oil. Using the Goulds installation tool, slide the seal rotary assembly onto the motor shaft and seat fully against the stationary seat. Remove the seal installation tool.

10. Install the impeller onto the motor shaft by turning the impeller on CLOCKWISE, tighten securely. Treat the impeller with Loctite™ #271 and securely install. When provided, securely install the impeller locknut.

11. Fill the motor cover with motor special insulating oil to within 12" (13 mm) of the seal chamber housing. Tape drain plug with Teflon™ tape and install plug securely.

12. Reassemble casing and new casing gasket to pump assembly by installing the four casing hex cap screws, torquing in sequence to 35 lbs ft (47 Ν m).

CAUTION

Hazardous pressure can cause personal injury or property damage.

FAILURE TO REMOVE DRAIN PLUG CAREFULLY CAN CAUSE HOT OIL TO ERUPT FROM OIL RESERVOIR CAUSING PERSONAL INJURY OR PROPERTY DAMAGE

NOTICE: FOLLOW THE INSTRUCTIONS PROVIDED IN THE “WIRING AND GROUNDING ” AND “OPERATION ” SECTIONS OF THE MANUAL AFTER UNIT DISASSEMBLY, REASSEMBLY.

POWER CABLE REPLACEMENT

1. To gain access to the motor cover screws follow steps 1 through 6 in the “MECHANICAL SEAL

3. Removal of the mechanical seal assembly (387) requires draining the special insulating oil from the motor cover. This is accomplished by removing the drain plug and draining the oil into an adequately sized clean receptacle. See “ENGINEERING DATA ” section for required volume.

4. To remove the impeller (101), it may be necessary to heat the impeller and impeller locknut (304), three phase motors only, with a torch. Use no more heat that is necessary, as excess heat will damage the mechanical seal. Secure the impeller from rotation, and remove

the impeller lock nut, by turning the lock nut COUNTERCLOCKWISE. Remove the impeller from the motor shaft by holding the motor shaft with a screw driver and turning the impeller COUNTER-

CLOCKWISE.

REPLACEMENT” section of this manual.

2. Remove the power cable strain relief (484B) assembly from the motor cover and slide up the cable.

3. Remove the four bearing housing socket head screws (371C). Carefully slide the motor cover from the motor assembly. DO NOT damage the power cable.

4. Disconnect the power cable wires from the motor assembly (338).

5. Remove cable from motor cover, inspect and replace as required, following the procedures provided.

NOTICE: DISCARD STRAIN RELIEF ASSEMBLY.

THEY CAN NOT BE REUSED.

6. Install new motor cable strain relief assembly onto cable, sliding the hex gland on first, then the washer and finally the packing. Insert the cables into the motor cover hole.

Pull an appropriate amount of cable through the motor cover to allow for connecting the cable leads. DO NOT tighten the strain relief gland.

5

Image 5
Contents Owner’s Information Table of ContentsPiping Lifting of PumpSliderail System Wiring and Grounding Access DoorsLiquid Level Controls Pump Motor Control PanelsPeriodic Maintenance MaintenanceFrequency Required Maintenance OperationMechanical Seal Replacement Disassembly/AssemblyPower Cable Replacement ClockwiseMotor Replacement Start Capacitor ReplacementVoltage Engineering DataAmps 1725458 376 338 372D 340 101 351 100 Repair Parts Diagram for Models 3885, 3886484B 457 436 341 112A 412M 371H 387371C 195C 351A 357Model 3885 Repair Parts Table Optional Lengths Model 3886 and 3887 Repair Parts TablePart Name Typical Plumbing and Installation Typical 2 Slide Rail InstallationSymptom Probable Cause Recommended Action Trouble ShootingTópico Información del propietarioÍndice Tuberías Levantamiento de la bombaSistema de riel corredizo Controles del nivel de líquido Puertas de accesoPaneles de control del motor de la bomba Alambrado y conexión a tierraMantenimiento OperaciónADVERTENCIA. Esto Puede Producir Graves Lesiones Personales Bloquear LA CorrienteDesmontaje/Reensamblaje Mantenimiento periódicoFrecuencia Mantenimiento Requerido Reemplazo DEL Sello MecánicoReemplazo DEL Motor Reemplazo DEL Condensador DE ArranqueDatos Eléctricos Datos de ingenieríaDatos Eléctricos 3886 Y Datos Eléctricos 38867BHF371H 387371C 195C 351A Diagrama de repuestos para los Modelos 3885, 3886 y484B 457 436 341 112A 412M Tabla de repuestos para el Modelo 11⁄2 HP Lbs Tabla de repuestos para los Modelos 3886 y1725 RPM 3450 RPM Máx ⁄3 HP Plomería e instalación típicas Instalación típica del riel corredizo de 2 pulgSíntoma Causa Probable Acción Recomendada Identificación y resolución de problemasSujet Informations pour le propriétaireTable des matières Tuyauterie Levage de la pompeSystème à rail de guidage glissière Trappes de visite Tableaux de commande des moteurs de pompeRégulateurs de niveau Câblage et mise à la terreEntretien périodique UtilisationEntretien Démontage et remontage « Remplacement DE LA GarnitureFréquence ET Mise À LA Terre » ET « Utilisation » DU ManuelRemplacement DU Moteur Remplacement DU Condensateur DE DémarrageIntensité a Données techniquesTension Dessin en coupe modèles 3885, 3886 et Pièces de rechange et matériaux modèle ’art Pièces de rechange et matériaux modèles 3886 et725 tr/min 450 tr/min ⁄3 hp ⁄2 hp ⁄4 hp 11⁄2 hpSystème à rail de guidage type de 2 po Installations typesAnomalies Causes Probables Correctifs Recommandés Diagnostic des anomalies