HP Hickory Rotis N/45WDG Changing Gas Orifices Changing the Main Gas Orifice, Venturi Assembly

Page 10

Hickory Industries, Inc.

1.9Changing Gas Orifices

1.9.1Changing the Main Gas Orifice

1.The venturi tubes and manifold valves are on the same side as the spit handles.

2.On each venturi, loosen the lock nuts (7/8" wrench) and then move the nut and the air intake cap all the way to the top of the nipple.

3.With a 3/4" wrench, loosen the nipple so that it can be removed from the venturi.

4.With the nipple/orifice assembly off, separate the main orifice from the nipple with a pipe wrench or a pair of pliers.

Nipple

Air Intake Cap

Lock Nut

Air Intake Adjustment

Main Orifice

Venturi Tube

Venturi Assembly

Re-assemble all of the components with the new main orifice. Make sure that the proper air intake adjustment is made for the new type of gas (according to the tables on page 9). The flames should be blue in color, must be stable, and must not "lift off" the burner.

4900 Westside Avenue, North Bergen, New Jersey 07047

N/45 Series Manual12/00

Tel: [201] 223-0050 Fax: [201] 223-0950

Page 10 of 38

Image 10
Contents Hickory Rotisseries Index Inital Steps II. Operating Instructions Electrical Connection Placing the MachineAssembling the Machine Gas ConnectionII Installation Instructions General Information Description of the Data PlateMachine Drawings and Dimensions Verification for use with Natural Gas Conversion and Adjustment InstructionsManifold Valve Natural Gas Flow Table Hickory Industries, Inc Venturi Assembly Changing Gas Orifices Changing the Main Gas OrificeNatural Gas 3211*Verbally confirm model 45 when ordering Pilot Burner Assembly3221* Verbally confirm model 45 when ordering Changing the Pilot OrificeChecking the Connected Gas Pressure Nominal Pressure Problem Cause Solution Testing or checking for safetyElectrical Diagram All Models Description of the Electrical ConnectionParts List for N /4 5WDG Qty Description Material Length Size ManufacturerParts List for N / 45WDG Contd Following parts are not shown in the diagramsHickory Industries, Inc Hickory Industries, Inc Hickory Industries, Inc II. Operating Instructions Start Up Shut DownWorking with the Rotisserie Manifold Valve Knob in Pilot PositionHickory Industries, Inc Using Angle Spits Chickens TiesTrussing Legs Pop-up Thermometer Using the Angle Spit Incorrectly Spitted Chicken Inserting Single Bottom Skewer Fastening Bottom SkewerInserting Chicken Locking Wings Inserting Double Skewers Completing the Load Hickory Industries, Inc Checking Chickens for Doneness Cooking other ProductsAt The End of Each Day Maintenance Procedures for Continuous Cook Rotisseries Hickory Industries, Inc Hickory Industries, Inc