HP Hickory Rotis N/45WDG, Hickory Rotis 45WDG PLUS II. Operating Instructions Start Up, Shut Down

Page 20

Hickory Industries, Inc.

II.Operating Instructions

1.0 Start Up

a.Switch the exhaust hood to on.

b.Open the gas cock at the rear of the machine.

c.Turn the knob on the manifold valve to the "pilot" position.

d.While pressing the "flow index" button down, place a match, or other type of ignition method, to the pilot burner until it is lit. Keep the knob pressed down for at least 40- 60 seconds so that the thermocouple tip warms up and the pilot flame remains lit.

e.Release the knob. The pilot flame should stay on.

f.Repeat the procedure for the other burners.

g.Turn the manifold valve knob to the desired setting ("on" must be lined up with the "flow index" button for high flame or maximum heat). The pipe burner should now light up.

h.Allow the unit to pre-heat for about 15 minutes.

i.When ready to load the spits with product, turn the light and the motor switches to the on position.

2.0Shut Down

a.Turn the manifold valve knobs to the "off" position if all flames are to be shut off. If the pilot light is to remain lit and only the pipe burners are to be shut off, turn the manifold valve knobs to the "pilot" position. Note that to turn the knobs to the "off" position, one must pull out on the locking mechanism on the knobs and then turn the valve to the off position.

b.After all of the loaded spits have been removed, turn the motor and lights off.

c.Close the gas cock at the rear of the machine if the pilot flames are also shut off.

d.Turn off the exhaust hood.

WARNING! Do not clean the machine or glass while these are hot! Everything should be cooled down before cleaning.

4900 Westside Avenue, North Bergen, New Jersey 07047

N/45 Series Manual12/00

Tel: [201] 223-0050 Fax: [201] 223-0950

Page 20 of 38

Image 20
Contents Hickory Rotisseries Index Inital Steps II. Operating Instructions Placing the Machine Assembling the MachineElectrical Connection Gas ConnectionII Installation Instructions General Information Description of the Data PlateMachine Drawings and Dimensions Manifold Valve Conversion and Adjustment InstructionsVerification for use with Natural Gas Natural Gas Flow Table Hickory Industries, Inc Venturi Assembly Changing Gas Orifices Changing the Main Gas OrificePilot Burner Assembly 3221* Verbally confirm model 45 when orderingNatural Gas 3211*Verbally confirm model 45 when ordering Changing the Pilot OrificeChecking the Connected Gas Pressure Nominal Pressure Problem Cause Solution Testing or checking for safetyElectrical Diagram All Models Description of the Electrical ConnectionParts List for N /4 5WDG Qty Description Material Length Size ManufacturerParts List for N / 45WDG Contd Following parts are not shown in the diagramsHickory Industries, Inc Hickory Industries, Inc Hickory Industries, Inc II. Operating Instructions Start Up Shut DownWorking with the Rotisserie Manifold Valve Knob in Pilot PositionHickory Industries, Inc Using Angle Spits Chickens TiesTrussing Legs Pop-up Thermometer Using the Angle Spit Incorrectly Spitted Chicken Inserting Single Bottom Skewer Fastening Bottom SkewerInserting Chicken Locking Wings Inserting Double Skewers Completing the Load Hickory Industries, Inc Checking Chickens for Doneness Cooking other ProductsAt The End of Each Day Maintenance Procedures for Continuous Cook Rotisseries Hickory Industries, Inc Hickory Industries, Inc