3.0 Working with the Rotisserie

A. Cooking Temperature

The desired temperature in the rotisserie can only be set with the manifold valve knob. Setting "on" is for the high flame setting and represents about 540°F. The grilling temperature can be reduced by turning the knob counter clock-wise (CCW), towards the "pilot" position.

Flow Index Button

Reduced Flame Setting

High Flame Setting

"Off" Locking Mechanism

Gas Control Lever

Manifold Valve Knob in "Pilot" Position

As a general rule, the higher the grilling temperature, the shorter the cooking time. However, when working with the Old Hickory rotisserie, one must consider that the temperatures will vary from top to bottom. The top of the unit will have higher temperatures due to the natural convection. The cooking temperatures indicated above refer to the top section of the machine. For this reason, the product on the top spits will be cooked faster than the product on the lower spits.

This factor allows for continuous cooking. As the top spits are ready, they should be removed. The spits directly below should then be moved up one spit position, thus freeing a spit position at the bottom of the unit. This bottom position can then be loaded with fresh, raw product. By loading raw product to the bottom, there is no danger of cross contamination.

WARNING: The only way to be sure that the product is completely cooked is by taking the internal temperatures. For example, with poultry, the internal temperature must be at least 185°F at the inner side of the thigh.

For example, when preparing chicken.

4900 Westside Avenue, North Bergen, New Jersey 07047

N/45 Series Manual12/00

Tel: [201] 223-0050 Fax: [201] 223-0950

Page 21 of 38

Image 21
Contents Hickory Rotisseries Index Inital Steps II. Operating Instructions Assembling the Machine Placing the MachineElectrical Connection Gas ConnectionDescription of the Data Plate II Installation Instructions General InformationMachine Drawings and Dimensions Conversion and Adjustment Instructions Verification for use with Natural GasManifold Valve Natural Gas Flow Table Hickory Industries, Inc Changing Gas Orifices Changing the Main Gas Orifice Venturi Assembly3221* Verbally confirm model 45 when ordering Pilot Burner AssemblyNatural Gas 3211*Verbally confirm model 45 when ordering Changing the Pilot OrificeChecking the Connected Gas Pressure Nominal Pressure Testing or checking for safety Problem Cause SolutionDescription of the Electrical Connection Electrical Diagram All ModelsQty Description Material Length Size Manufacturer Parts List for N /4 5WDGFollowing parts are not shown in the diagrams Parts List for N / 45WDG ContdHickory Industries, Inc Hickory Industries, Inc Hickory Industries, Inc Shut Down II. Operating Instructions Start UpManifold Valve Knob in Pilot Position Working with the RotisserieHickory Industries, Inc Chickens Ties Using Angle SpitsTrussing Legs Pop-up Thermometer Using the Angle Spit Incorrectly Spitted Chicken Fastening Bottom Skewer Inserting Single Bottom SkewerInserting Chicken Locking Wings Inserting Double Skewers Completing the Load Hickory Industries, Inc Cooking other Products Checking Chickens for DonenessAt The End of Each Day Maintenance Procedures for Continuous Cook Rotisseries Hickory Industries, Inc Hickory Industries, Inc