HP Hickory Rotis N/45WDG manual Maintenance Procedures for Continuous Cook Rotisseries

Page 36

Hickory Industries, Inc.

10.Maintenance Procedures for Continuous Cook Rotisseries

The most effective maintenance procedure that you can perform will be the daily cleaning procedure.

Monthly:

To ensure that the burner is operating efficiently, remove the ceramics and use a paper clip to clean any debris from the burner openings.

To ensure proper air/gas mixture, the venturi air inlet gap needs to be cleaned. This can be done using a paring knife or business card. Refer to the operating manual.

Every 6 Months:

To ensure that the shaft worm nylon gears properly mesh with the spit gears, place a spit into each spit position with the motor running. If the gears jump or do not align properly, adjust them using the allen wrench provided – DO NOT OVER TIGHTEN THE SCREWS.

Every 12 Months:

Inspect the spit plates and verify that the brass oil lite bushings are in place for each spit position. Replace any worn or missing bushings.

Remove the glass and inspect for scratches and or chips. If any are found replace the glass as soon as possible. Also, inspect the glass trolleys. If they are worn, replace them.

Units with sliding side doors – the upper and lower slides needed to be greased.

4900 Westside Avenue, North Bergen, New Jersey 07047

N/45 Series Manual12/00

Tel: [201] 223-0050 Fax: [201] 223-0950

Page 36 of 38

Image 36
Contents Hickory Rotisseries Index Inital Steps II. Operating Instructions Placing the Machine Assembling the MachineElectrical Connection Gas ConnectionII Installation Instructions General Information Description of the Data PlateMachine Drawings and Dimensions Conversion and Adjustment Instructions Verification for use with Natural GasManifold Valve Natural Gas Flow Table Hickory Industries, Inc Venturi Assembly Changing Gas Orifices Changing the Main Gas OrificePilot Burner Assembly 3221* Verbally confirm model 45 when orderingNatural Gas 3211*Verbally confirm model 45 when ordering Changing the Pilot OrificeChecking the Connected Gas Pressure Nominal Pressure Problem Cause Solution Testing or checking for safetyElectrical Diagram All Models Description of the Electrical ConnectionParts List for N /4 5WDG Qty Description Material Length Size ManufacturerParts List for N / 45WDG Contd Following parts are not shown in the diagramsHickory Industries, Inc Hickory Industries, Inc Hickory Industries, Inc II. Operating Instructions Start Up Shut DownWorking with the Rotisserie Manifold Valve Knob in Pilot PositionHickory Industries, Inc Using Angle Spits Chickens TiesTrussing Legs Pop-up Thermometer Using the Angle Spit Incorrectly Spitted Chicken Inserting Single Bottom Skewer Fastening Bottom SkewerInserting Chicken Locking Wings Inserting Double Skewers Completing the Load Hickory Industries, Inc Checking Chickens for Doneness Cooking other ProductsAt The End of Each Day Maintenance Procedures for Continuous Cook Rotisseries Hickory Industries, Inc Hickory Industries, Inc