HP GS1280 CPU Building Block Modules Mandatory, Supported Configurations, Full Use CPU Building

Page 10

QuickSpecs

HP AlphaServer GS1280 Systems

Systems

Step 3 - CPU Building Block Modules – Mandatory

M=Mandatory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

O=Optional

 

 

 

 

 

 

 

 

Supported Configurations

 

 

 

 

 

 

 

 

CPUs

2

4

6

8

10

12

14

16 18 20 22 24 26

28

30

32

36

40

44

48

52

56

60

64

Dual CPU Modules

1

2

3

4

5

6

7

8

9

10 11 12 13

14

15

16

18

20

22

24

26

28

30

32

GS1280 Model 8

M

O

O

O

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GS1280 Model 16

M

O

O

O

O

O

O

O

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

GS1280 Model 32

M

O

O

O

O

O

O

O O O O

O O

O

O

O

-

-

-

-

-

-

-

-

GS1280 Model 64

-

-

-

-

-

-

-

M

-

-

-

O

-

-

-

O

O

O

O

O

O

O

O

O

Configuration Guidelines

1.CPU Building Blocks with different clock speeds can co-exist in one system, but must be separated into hard partitions where the CPUs have the same speed.

2.CPU Building Block or instant Capacity (iCAP) CPU Building Block Modules type (Tru64 UNIX or OpenVMS) must match the base system operating system selected in Step 2, or purchase a base operating system upgrade license to match the license with the CPU Building Block Module.

Full Use CPU Building

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1300

3X-KN72D-AB

Block Modules

MHz, Tru64 UNIX SMP License

 

 

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1300

3X-KN72D-AC

 

MHz, OpenVMS SMP License

 

 

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150

3X-KN72C-AB

 

MHz, Tru64 UNIX SMP License

 

 

AlphaServer GS1280 Dual CPU Building Block Module, 2xEV7 CPUs, 1150

3X-KN72C-AC

 

MHz, OpenVMS SMP License

 

 

 

 

Configuration and Use of instant Capacity (iCAP) CPUs

The instant Capacity (iCAP) program gives HP customers the option to purchase add-on CPU modules at a reduced price and install those modules in systems ready to activate instantly when needed for extra computational capacity. To use the iCAP program for AlphaServers:

1.Order and install iCAP CPU modules along with Full Use CPUs. The total number of Full Use CPU Building Block Modules plus iCAP CPU Building Bock Modules must adhere to the limits outlined above for GS1280 systems.

2.Use the iCAP software (supplied with the iCAP CPU Module) to set iCAP CPUs inactive. As long as the total number of active CPUs does not exceed the number of licensed CPUs owned for the system, the owner may choose which CPUs to designate as iCAP.

3.Inactive iCAP CPUs cannot include the primary CPU, CPUs responsible for hardware interrupts, CPUs being used by an application when configuring iCAP, or a CPU connected to an I/O Building Block Drawer.

4.Activate the iCAP CPUs for First Use when extra capacity is needed, and then promptly purchase the iCAP Enablement (Right-to-Use).

iCAP CPU Building Block Module + iCAP Enablement = Full Use CPU Building Block Module

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 10

Image 10
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Processor Boot/DiagnosticPower Supplies Cache MemoryQuickSpecs Optional Purchases Recommended ServicesRequirements System Requirements Requirements for PartitionsLicensing Systems for Both OpenVMS and Tru64 Unix Configuration GuidelinesQB-63PAQ-AC Select Base System Mandatory System Management Hardware/Software RequirementsRacks CPU Building Block Modules Mandatory Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs Full Use CPU BuildingTerms and Definitions ICAP EnablementICAP CPU Building First USECPU Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesScsi USBDVD CD-RW Type a Power Distribution Units MandatoryPower Distribution UnitsType a Power Dual AC Power OptionalDistribution Units QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents AGP Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput Overall System Capacities for I/O Adapters and ControllersMaximum High Performance I/O Drawers Four Per systemPCI-X/PCI slots in Standard I/O Drawers MHz PCI-X/PCI slots in High Performance Drawers4X AGP Adapters Installed Max Bus SpeedPCI Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsPort Bus # Slot # Signal Voltage Adapters Installed Max Bus SpeedTo EV7 U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGHole Pattern Vertical Rack CapacityRail Spacing Max Payload specdRackmount Kits 3X-DEGXA-TR DescriptionEthernet Network Interface Cards 3X-DEGXA-SRAsynchronous Communications Network Interface Cards CCMAB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMFB-BAMemory Channel Fibre Channel Controllers Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Cipca AdapterBus Model MSA30, Dual StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayHP StorageWorks Disk Array xp10000 EVA8000Model EVA4000 EVA6000 EVA8000 DrivesHP StorageWorks DLT VS Tape Drive Family HP StorageWorks Sdlt Tape Drive FamilySdlt External DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalAutoloader Rack Mount Kit HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO HP StorageWorks MSL2024 Tape LibraryHP StorageWorks MSL6000 Tape Libraries Maximum DataTransfer native MSL6026 MSL6030 MSL6052 MSL6060 Form FactorProduct height within Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Rack Maximum CapacityMaximum Raw SwitchesVLS Raw Capacity Capacity Usable CapacityOpenVMS Note Rackmount Keyboard/Drawer Keyboard/Monitor Options Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines CAT5e CablesCarbon/Silver Flat Monitor Power CordsCarbon/Silver Monitors Panel MonitorsGraphics Adapters Graphics SoftwareQA-6ADAA-GZ QA-6ADAA-H8OpenVMS OpenVMS Galaxy Galaxy Soft Partition RulesProgram Features Principal Server HP Support Plus Hardware and Software Support Services OptionalService Part Numbers System Codes forCritical Services HP ProactiveInstallation and Startup Program Features Additional ServicesInstallation HP O/SYT-VISIT-B1 ServiceBasic Integration YT-VISIT-R1Configurations Clustering ServicePartitioning Service Full CustomKit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04Power Distribution Unit 3X-H7606-BA North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA PDU required for all GS1280 ModelsGS1280 Models 3X-H7606 Power Distribution Unit Power Required, KvaPower Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsEnvironmental Operating Non-Operating Service Clearances-All Operating ModelsAcoustics Declared values per ISO 9296 and ISO